Doses from ionising radiation in paediatric cardiac catheterisations in Norway 1975–2021

Paediatric patients with congenital heart disease often undergo cardiac catheterisation procedures and are exposed to considerable ionising radiation early in life. This study aimed to develop a method for estimating the dose area product (<i>P</i><sub>KA</sub>) from paediatric cardiac catheterisation procedures (1975-1989) at a national centre for paediatric cardiology and to evaluate trends in<i>P</i><sub>KA</sub>and exposure parameters until 2021. Data from 2200 catheterisation procedures on 1685 patients (1975-1989) and 4184 procedures on 2139 patients (2000-2021) under 18 years of age were retrospectively collected.<i>P</i><sub>KA</sub>values were missing for 1975-1989 but available from 2000 onward. The missing<i>P</i><sub>KA</sub>was estimated from air kerma and beam area, based on exposure records and input from clinicians working at that time.<i>P</i><sub>KA</sub>trends were analysed over time and age. There was a 71% reduction in median<i>P</i><sub>KA</sub>from the period 1975-1989 (median 6.63 Gy cm<sup>2</sup>) to 2011-2021 (1.91 Gy cm<sup>2</sup>). The<i>P</i><sub>KA</sub>increases significantly (<i>p</i>= 0.0001) with patient age, which was associated with body weight. Approximately 80% of the total<i>P</i><sub>KA</sub>was from cine acquisition in 1975-1989, while 20% was from fluoroscopy. The<i>P</i><sub>KA</sub>estimate during 1975-1989 was considerably impacted by the assumptions of missing parameters such as tube filtration, focus-to-heart distance, beam area, and number of cine series. The decreasing trend in<i>P</i><sub>KA</sub>values was attributed to advancements in both technologies and clinical practices. The high contribution of cine acquisition to the total dose during 1975-1989 was due to factors such as a high frame rate, multiple acquisitions, and high tube current. The estimated<i>P</i><sub>KA</sub>values for the period 1975-1989 are of importance for the dose reconstruction and risk assessments in the EU epidemiology project Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics(HARMONIC).

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2024-11-21
DOI
https://doi.org/10.1088/1361-6498/ad958e
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Doses from ionising radiation in paediatric cardiac catheterisations in Norway 1975–2021

Gaute Døhlen, Marianna Meo, Bjørn Helge Østerås, H.M. Olerud et al.
Journal of Radiological Protection
Radiation Dose and Imaging
article

Doses from ionising radiation in paediatric cardiac catheterisations in Norway 1975–2021

Gaute Døhlen, Marianna Meo, Bjørn Helge Østerås, H.M. Olerud, Andréas Jahnen, Isabelle Thierry-Chef, Trude Eid Robsahm, Jérémie Dabin, S Afroz, U S Thevathas
article en

Abstract

Paediatric patients with congenital heart disease often undergo cardiac catheterisation procedures and are exposed to considerable ionising radiation early in life. This study aimed to develop a method for estimating the dose area product (<i>P</i><sub>KA</sub>) from paediatric cardiac catheterisation procedures (1975-1989) at a national centre for paediatric cardiology and to evaluate trends in<i>P</i><sub>KA</sub>and exposure parameters until 2021. Data from 2200 catheterisation procedures on 1685 patients (1975-1989) and 4184 procedures on 2139 patients (2000-2021) under 18 years of age were retrospectively collected.<i>P</i><sub>KA</sub>values were missing for 1975-1989 but available from 2000 onward. The missing<i>P</i><sub>KA</sub>was estimated from air kerma and beam area, based on exposure records and input from clinicians working at that time.<i>P</i><sub>KA</sub>trends were analysed over time and age. There was a 71% reduction in median<i>P</i><sub>KA</sub>from the period 1975-1989 (median 6.63 Gy cm<sup>2</sup>) to 2011-2021 (1.91 Gy cm<sup>2</sup>). The<i>P</i><sub>KA</sub>increases significantly (<i>p</i>= 0.0001) with patient age, which was associated with body weight. Approximately 80% of the total<i>P</i><sub>KA</sub>was from cine acquisition in 1975-1989, while 20% was from fluoroscopy. The<i>P</i><sub>KA</sub>estimate during 1975-1989 was considerably impacted by the assumptions of missing parameters such as tube filtration, focus-to-heart distance, beam area, and number of cine series. The decreasing trend in<i>P</i><sub>KA</sub>values was attributed to advancements in both technologies and clinical practices. The high contribution of cine acquisition to the total dose during 1975-1989 was due to factors such as a high frame rate, multiple acquisitions, and high tube current. The estimated<i>P</i><sub>KA</sub>values for the period 1975-1989 are of importance for the dose reconstruction and risk assessments in the EU epidemiology project Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics(HARMONIC).

Journal of Radiological ProtectionVol. 44(4)
Oslo University Hospital (NO), Norwegian Institute of Public Health (NO), Buskerud University College (NO), Drammen Hospital (NO), University of South-Eastern Norway (NO), Luxembourg Institute of Science and Technology (LU), Belgian Nuclear Research Centre (BE), Cancer Registry of Norway (NO), Barcelona Institute for Global Health (ES)
FP7 Euratom
Good health and well-being
Openalex Percentile: Top 65%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.