Direct measurements of the conventional and rotational magnetocaloric effects in Gd thick films

Abstract Magnetic refrigeration (MR) offers a sustainable and emission-free solution to the prevalent heat-pumping systems used worldwide. Typically, it utilizes the magnetocaloric effect (MCE) to achieve cooling by changing the external magnetic field intensity. However, an alternative approach involves maintaining a fixed field intensity while manipulating its orientation to induce temperature changes, in an effect known as the rotating MCE (RMCE). While the RMCE has been extensively studied in materials with magnetocrystalline anisotropy, its investigation in polycrystalline magnetocaloric samples with asymmetric shapes has been lacking until recently. In this case, the RMCE is induced by the demagnetizing effect, which becomes more pronounced in high aspect-ratio sample geometries exhibiting different effective demagnetizing factors at different orientations, such as in films. In this work, we characterize the conventional and rotational MCE of 40 μ m-thick gadolinium films through magnetization and direct temperature measurements. The maximum adiabatic temperature change achieved under a 1 T magnetic field was 2.05 K when the film was oriented in plane with the field and 1.25 K when the film was perpendicular to the magnetic field, corresponding to an adiabatic temperature difference of around 0.8 K which may be induced through magnetic field rotation. Additionally, the maximum adiabatic temperature change upon rotation is shown to exhibit a non-monotonous behavior with field intensity, displaying a peak value for field intensities of around 0.8 T. The high aspect ratio of the Gd film has been demonstrated to considerably enhance the intensity of demagnetizing field-based RMCE compared to bulk samples, paving the way for future research in this emerging field of MR cooling.

Authors

Institutions

Publication Details

Journal
Journal of Physics D Applied Physics
Published
2024-11-21
DOI
https://doi.org/10.1088/1361-6463/ad958f
Citations
3
Primary Topic
Magnetic and transport properties of perovskites and related materials
Type
article
Field-Weighted Citation Impact
0.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct measurements of the conventional and rotational magnetocaloric effects in Gd thick films

D J Silva, Tino Gottschall, João S. Amaral, Timo Niehoff et al.
3 citations
Journal of Physics D Applied Physics
Magnetic and transport properties of perovskites and related materials
0.35
article

Direct measurements of the conventional and rotational magnetocaloric effects in Gd thick films

D J Silva, Tino Gottschall, João S. Amaral, Timo Niehoff, Erika Fontana, Nora M. Dempsey, J. Wosnitza, Thibaut Devillers, J.H. Belo, R. Kiefe, R. Almeida, Celina Siqueira Barbosa Pereira
article en
3 citations

Abstract

Abstract Magnetic refrigeration (MR) offers a sustainable and emission-free solution to the prevalent heat-pumping systems used worldwide. Typically, it utilizes the magnetocaloric effect (MCE) to achieve cooling by changing the external magnetic field intensity. However, an alternative approach involves maintaining a fixed field intensity while manipulating its orientation to induce temperature changes, in an effect known as the rotating MCE (RMCE). While the RMCE has been extensively studied in materials with magnetocrystalline anisotropy, its investigation in polycrystalline magnetocaloric samples with asymmetric shapes has been lacking until recently. In this case, the RMCE is induced by the demagnetizing effect, which becomes more pronounced in high aspect-ratio sample geometries exhibiting different effective demagnetizing factors at different orientations, such as in films. In this work, we characterize the conventional and rotational MCE of 40 μ m-thick gadolinium films through magnetization and direct temperature measurements. The maximum adiabatic temperature change achieved under a 1 T magnetic field was 2.05 K when the film was oriented in plane with the field and 1.25 K when the film was perpendicular to the magnetic field, corresponding to an adiabatic temperature difference of around 0.8 K which may be induced through magnetic field rotation. Additionally, the maximum adiabatic temperature change upon rotation is shown to exhibit a non-monotonous behavior with field intensity, displaying a peak value for field intensities of around 0.8 T. The high aspect ratio of the Gd film has been demonstrated to considerably enhance the intensity of demagnetizing field-based RMCE compared to bulk samples, paving the way for future research in this emerging field of MR cooling.

Journal of Physics D Applied PhysicsVol. 58(7)
Universidade do Porto (PT), Helmholtz-Zentrum Dresden-Rossendorf (DE), Institut Néel (FR), University of Aveiro (PT), Technische Universität Dresden (DE)
Universidade de Aveiro, CERN, Agence Nationale de la Recherche, Ministério da Ciência, Tecnologia e Ensino Superior, Universidade do Porto, Centro de Investigação em Materiais Cerâmicos e Compósitos, Fundação para a Ciência e a Tecnologia
Responsible consumption and production
Openalex Percentile: Top 50%
Magnetic and transport properties of perovskites and related materials
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.