A collaborative study to establish the second national standard for antithrombin concentrate in Korea

This study aimed to establish a second national standard for antithrombin (AT) concentrate that can be used for potency assays of AT products. A collaborative study was conducted involving four laboratories, including national control laboratories and manufacturers in Korea, and the suitability of a candidate material to serve as the second national standard for AT concentrate was evaluated. The candidate material was manufactured using a process approved for Good Manufacturing Practices. The potency of the candidate was determined using the heparin cofactor chromogenic method. The candidate was calibrated against the third International Standard for AT concentrate (code 06/166). Participants provided data from 58 independent assays. Combined potency estimates were calculated by determining the geometric means of the results obtained from all assays performed at individual laboratories. The overall potency assessments were subsequently established as the geometric means of all results collected from all laboratories. According to the collaborative study results, the intra- and inter-laboratory variability showed acceptable geometric coefficient of variation of 1.2 %-3.4 % and 2.4 % respectively, and it deemed to serve as the Korean national standard for AT concentrate with the assigned potency as follows: 32.1 IU/vial (95 % confidence interval; 31.7-32.5 IU/vial).

Authors

Institutions

Publication Details

Journal
Biologicals
Published
2024-11-21
DOI
https://doi.org/10.1016/j.biologicals.2024.101807
Primary Topic
Venous Thromboembolism Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A collaborative study to establish the second national standard for antithrombin concentrate in Korea

Ha-Young Koh, Chan Woong Choi, Su Kyoung Seong, Hyun Jeong Kim et al.
Biologicals
Venous Thromboembolism Diagnosis and Management
article

A collaborative study to establish the second national standard for antithrombin concentrate in Korea

Ha-Young Koh, Chan Woong Choi, Su Kyoung Seong, Hyun Jeong Kim, In‐Soo Shin, Young Hyoun Yi, Young Hoon Kim, Youngju Choi
article en

Abstract

This study aimed to establish a second national standard for antithrombin (AT) concentrate that can be used for potency assays of AT products. A collaborative study was conducted involving four laboratories, including national control laboratories and manufacturers in Korea, and the suitability of a candidate material to serve as the second national standard for AT concentrate was evaluated. The candidate material was manufactured using a process approved for Good Manufacturing Practices. The potency of the candidate was determined using the heparin cofactor chromogenic method. The candidate was calibrated against the third International Standard for AT concentrate (code 06/166). Participants provided data from 58 independent assays. Combined potency estimates were calculated by determining the geometric means of the results obtained from all assays performed at individual laboratories. The overall potency assessments were subsequently established as the geometric means of all results collected from all laboratories. According to the collaborative study results, the intra- and inter-laboratory variability showed acceptable geometric coefficient of variation of 1.2 %-3.4 % and 2.4 % respectively, and it deemed to serve as the Korean national standard for AT concentrate with the assigned potency as follows: 32.1 IU/vial (95 % confidence interval; 31.7-32.5 IU/vial).

BiologicalsVol. 89
Ministry of Food and Drug Safety (KR), National Institute of Food and Drug Safety Evaluation (KR)
Ministry of Food and Drug Safety, National Institute of Food and Drug Safety Evaluation
Partnerships for the goals
Openalex Percentile: Top 58%
Venous Thromboembolism Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A collaborative study to establish the second national standard for antithrombin concentrate in Korea — Ha-Young Koh, Chan Woong Choi, et al. · Biologicals (2024) | TGRS Research Map | TGRS