First Experience Using a New Minimally Invasive Screw–Rod System for Completely Percutaneous Pedicle Screw Fixation of the Cervical Spine

In contrast to the thoracolumbar spine, where pedicle screws can be inserted via a minimally invasive, percutaneous technique through small skin incisions, all previously available cervical instrumentation systems required a larger midline incision, especially for rod insertion. Screw placement via small incisions reduces the risk of wound healing disorders and blood loss, and patients can be mobilized more quickly and with less pain. In 2022, a cervical, minimally invasive stabilization system became available for the complete percutaneous insertion of both cervical pedicle screws and rods. We report on the first results and experiences with this new technology.In this retrospective case series, we included patients with cervical instability treated by minimally invasive percutaneous cervical and upper thoracic spine pedicle screw and rod insertion between August 2022 and August 2023. Intra- and postoperative complications as well as revision surgeries were recorded. The screw position was evaluated by three examiners in the postoperative computed tomography (CT) using the Bredow classification.Our series includes six male patients (age = 56.9 ± 12.9 years; body mass index [BMI] = 29.8 ± 9.6 kg/m<sup>2</sup>). The indication for surgery was trauma, tumor, and degenerative stenosis in two patients each. An excellent/good screw position (Bredow 1 and 2) was found in 84.4% of the screws (n = 27/32). None of the screws rated as Bredow 3 (<i>n</i> = 2/32) or Bredow 4 (<i>n</i> = 3/32) resulted in a neurological deficit or radicular pain and none had to be repositioned. No neurologic complication or revision surgery occurred. As a complication not directly related to the surgery technique, one patient died of a pulmonary lung embolism on the seventh postoperative day.The results of this study indicate that minimally invasive percutaneous implantation of a pedicle screw-rod system is also possible in the cervical spine with sufficient accuracy using intraoperative navigation. However, technical details, possible pitfalls and finally careful patient selection must be taken into account.

Authors

Institutions

Publication Details

Journal
Journal of Neurological Surgery Part A Central European Neurosurgery
Published
2024-11-21
DOI
https://doi.org/10.1055/a-2479-5742
Citations
3
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
1.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First Experience Using a New Minimally Invasive Screw–Rod System for Completely Percutaneous Pedicle Screw Fixation of the Cervical Spine

Jan‐Helge Klingler, Ralf Watzlawick, Marc Hohenhaus, Florian Volz et al.
3 citations
Journal of Neurological Surgery Part A Central European Neurosurgery
Spinal Fractures and Fixation Techniques
1.72
article

First Experience Using a New Minimally Invasive Screw–Rod System for Completely Percutaneous Pedicle Screw Fixation of the Cervical Spine

Jan‐Helge Klingler, Ralf Watzlawick, Marc Hohenhaus, Florian Volz, Jürgen Beck, Christoph Scholz, U. Hubbe
article en
3 citations

Abstract

In contrast to the thoracolumbar spine, where pedicle screws can be inserted via a minimally invasive, percutaneous technique through small skin incisions, all previously available cervical instrumentation systems required a larger midline incision, especially for rod insertion. Screw placement via small incisions reduces the risk of wound healing disorders and blood loss, and patients can be mobilized more quickly and with less pain. In 2022, a cervical, minimally invasive stabilization system became available for the complete percutaneous insertion of both cervical pedicle screws and rods. We report on the first results and experiences with this new technology.In this retrospective case series, we included patients with cervical instability treated by minimally invasive percutaneous cervical and upper thoracic spine pedicle screw and rod insertion between August 2022 and August 2023. Intra- and postoperative complications as well as revision surgeries were recorded. The screw position was evaluated by three examiners in the postoperative computed tomography (CT) using the Bredow classification.Our series includes six male patients (age = 56.9 ± 12.9 years; body mass index [BMI] = 29.8 ± 9.6 kg/m<sup>2</sup>). The indication for surgery was trauma, tumor, and degenerative stenosis in two patients each. An excellent/good screw position (Bredow 1 and 2) was found in 84.4% of the screws (n = 27/32). None of the screws rated as Bredow 3 (<i>n</i> = 2/32) or Bredow 4 (<i>n</i> = 3/32) resulted in a neurological deficit or radicular pain and none had to be repositioned. No neurologic complication or revision surgery occurred. As a complication not directly related to the surgery technique, one patient died of a pulmonary lung embolism on the seventh postoperative day.The results of this study indicate that minimally invasive percutaneous implantation of a pedicle screw-rod system is also possible in the cervical spine with sufficient accuracy using intraoperative navigation. However, technical details, possible pitfalls and finally careful patient selection must be taken into account.

Journal of Neurological Surgery Part A Central European NeurosurgeryVol. 86(06)
University of Freiburg (DE), University Medical Center Freiburg (DE)
Good health and well-being
Openalex Percentile: Top 14%
Spinal Fractures and Fixation Techniques
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.