Application of the Reverse Pulse Technique for Worst Case Transient Analysis in HPC PDN Design
The reverse pulse technique (RPT) predicts peak voltage deviation in the presence of worst case transient (WCT) load current. While RPT has been vetted through simulation, this paper addresses the practical application in lab hardware.
Authors
- A. P. Hickman (ORCID: https://orcid.org/0000-0001-5180-527X)
- Jordan R. Keuseman
- Clifton R. Haider (ORCID: https://orcid.org/0000-0002-5869-432X)
- Chad M. Smutzer
Institutions
- Mayo Clinic (US)
Publication Details
- Published
- 2024-10-06
- DOI
- https://doi.org/10.1109/epeps61853.2024.10754562
- Primary Topic
- Engineering and Test Systems
- Type
- article
- Field-Weighted Citation Impact
- 0.00