Sensor-Free Strategy for Estimating Guidewire/Catheter Shape and Contact Force in Endovascular Interventions

Accurate assessment of guidewire shape and contact forces is critical for autonomous robotic endovascular procedures. However, existing sensor-based approaches often require modifications to standard guidewires or the use of custom-made alternatives, which can hinder integration into conventional surgical workflows and increase costs. Moreover, the sensor-based method can only obtain partial force information. This letter aimed to develop a novel sensor-free two-step computational method for estimating overall guidewire shape and forces using only routinely obtainable information. The vascular space is discretized into multiple mesh points along the centerline to form a graph. Based on an energy equation, the lowest energy path between the start point (the insertion position) and the endpoint (the guidewire tip position) is searched as the initial shape of the guidewire. This initial shape, along with the known insertion length, is then input into a finite element model to compute the final guidewire configuration and contact forces. The method was validated through 3 rounds of testing in 3 phantom models at 4 different insertion lengths. In 11 successful experimental scenarios, the estimated guidewire shapes closely matched the actual shapes, with an average root mean square error of 0.50 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 0.12 mm. The contact force estimation achieved an average accuracy of 91.9 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 2.9%, with an average angular deviation of 1.94 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 1.03<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^\circ$</tex-math></inline-formula> from measured values.

Authors

Institutions

Publication Details

Journal
IEEE Robotics and Automation Letters
Published
2024-11-21
DOI
https://doi.org/10.1109/lra.2024.3504236
Citations
1
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensor-Free Strategy for Estimating Guidewire/Catheter Shape and Contact Force in Endovascular Interventions

Huan Zhao, Naner Li, Han Ding, Yiwei Wang
1 citations
IEEE Robotics and Automation Letters
Peripheral Artery Disease Management
0.57
article

Sensor-Free Strategy for Estimating Guidewire/Catheter Shape and Contact Force in Endovascular Interventions

Huan Zhao, Naner Li, Han Ding, Yiwei Wang
article en
1 citations

Abstract

Accurate assessment of guidewire shape and contact forces is critical for autonomous robotic endovascular procedures. However, existing sensor-based approaches often require modifications to standard guidewires or the use of custom-made alternatives, which can hinder integration into conventional surgical workflows and increase costs. Moreover, the sensor-based method can only obtain partial force information. This letter aimed to develop a novel sensor-free two-step computational method for estimating overall guidewire shape and forces using only routinely obtainable information. The vascular space is discretized into multiple mesh points along the centerline to form a graph. Based on an energy equation, the lowest energy path between the start point (the insertion position) and the endpoint (the guidewire tip position) is searched as the initial shape of the guidewire. This initial shape, along with the known insertion length, is then input into a finite element model to compute the final guidewire configuration and contact forces. The method was validated through 3 rounds of testing in 3 phantom models at 4 different insertion lengths. In 11 successful experimental scenarios, the estimated guidewire shapes closely matched the actual shapes, with an average root mean square error of 0.50 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 0.12 mm. The contact force estimation achieved an average accuracy of 91.9 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 2.9%, with an average angular deviation of 1.94 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\pm$</tex-math></inline-formula> 1.03<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$^\circ$</tex-math></inline-formula> from measured values.

IEEE Robotics and Automation LettersVol. 10(1)
Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China
Zero hunger
Openalex Percentile: Top 27%
Peripheral Artery Disease Management
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.