Toward Wearable Electromyography for Personalized Musculoskeletal Trunk Models Using an Inverse Synergy-Based Approach

Electromyography (EMG)-driven musculoskeletal models (EMS) of the trunk are used for estimating lumbosacral joint moments and compressive loads during lifting tasks. These models provide personalized estimates of the parameters using information from many sensors. However, to advance technology from labs to workplaces, there is a need for sensor reduction to improve wearability and applicability. Therefore we introduce an EMG sensor reduction approach based on inverse synergy extrapolation, to reconstruct unmeasured EMG signals for different box-lifting techniques. 12 participants performed an array of tasks (squat, stoop, unilateral twist and bilateral twist) with different weights (0 kg, 7.5 kg and 15 kg). We found that two synergies were sufficient to explain the different lifting tasks (median variance accounted for of 0.91). Building upon this, we used two sensors at optimal subject-specific muscle locations to reconstruct the EMG of four unmeasured channels. Evaluation of the reconstructed and reference EMG showed median coefficients of determination <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$(R^{2})$ </tex-math></inline-formula> between 0.70 and 0.86, with median root mean squared errors (RMSE) ranging from 0.02 to 0.04 relative to maximal voluntary contraction. This indicates that our proposed method shows promise for sensor reduction for driving a trunk EMS for ambulatory biomechanical risk assessment in occupational settings and exoskeleton control.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Robotics and Bionics
Published
2024-11-21
DOI
https://doi.org/10.1109/tmrb.2024.3503900
Citations
4
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward Wearable Electromyography for Personalized Musculoskeletal Trunk Models Using an Inverse Synergy-Based Approach

Massimo Sartori, Mohamed Irfan Mohamed Refai, Jan Willem A. Rook
4 citations
IEEE Transactions on Medical Robotics and Bionics
Muscle activation and electromyography studies
0.74
article

Toward Wearable Electromyography for Personalized Musculoskeletal Trunk Models Using an Inverse Synergy-Based Approach

Massimo Sartori, Mohamed Irfan Mohamed Refai, Jan Willem A. Rook
article en
4 citations

Abstract

Electromyography (EMG)-driven musculoskeletal models (EMS) of the trunk are used for estimating lumbosacral joint moments and compressive loads during lifting tasks. These models provide personalized estimates of the parameters using information from many sensors. However, to advance technology from labs to workplaces, there is a need for sensor reduction to improve wearability and applicability. Therefore we introduce an EMG sensor reduction approach based on inverse synergy extrapolation, to reconstruct unmeasured EMG signals for different box-lifting techniques. 12 participants performed an array of tasks (squat, stoop, unilateral twist and bilateral twist) with different weights (0 kg, 7.5 kg and 15 kg). We found that two synergies were sufficient to explain the different lifting tasks (median variance accounted for of 0.91). Building upon this, we used two sensors at optimal subject-specific muscle locations to reconstruct the EMG of four unmeasured channels. Evaluation of the reconstructed and reference EMG showed median coefficients of determination <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$(R^{2})$ </tex-math></inline-formula> between 0.70 and 0.86, with median root mean squared errors (RMSE) ranging from 0.02 to 0.04 relative to maximal voluntary contraction. This indicates that our proposed method shows promise for sensor reduction for driving a trunk EMS for ambulatory biomechanical risk assessment in occupational settings and exoskeleton control.

IEEE Transactions on Medical Robotics and BionicsVol. 7(1)
University of Twente (NL)
European Commission, European Research Council
Openalex Percentile: Top 31%
Muscle activation and electromyography studies
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Toward Wearable Electromyography for Personalized Musculoskeletal Trunk Models Using an Inverse Synergy-Based Approach — Massimo Sartori, Mohamed Irfan Mohamed Refai, et al. · IEEE Transactions on Medical Robotics and Bionics (2024) | TGRS Research Map | TGRS