Right atrial appendage accessory pathway causing pseudo-refractory atrioventricular reentrant tachycardia
Catheter ablation is the first-line therapy for symptomatic atrioventricular reentrant tachycardia (AVRT). Pseudo-refractory AVRT may stem from misdiagnosis, use of inadequate ablation methods, or the presence of additional concealed or unusual located pathways that initiate or sustain the tachycardia. We present a case of right atrial appendage accessory pathway—a rare and overlooked cause of AVRT—to illustrate the importance of raising suspicion for this condition when standard mapping and ablation around the tricuspid valve annulus fail to eliminate pathway conduction. Furthermore, we present a straightforward, effective approach for localizing the pathway site and safely performing irrigated ablation at the base of the right atrial appendage.
Authors
- Allêh Nogueira (ORCID: https://orcid.org/0000-0001-5995-6179)
- Lucas Hollanda Oliveira (ORCID: https://orcid.org/0000-0002-6770-4462)
- Christian Moreno Luize (ORCID: https://orcid.org/0000-0002-4024-1963)
- Ricardo Sobral de Carvalho (ORCID: https://orcid.org/0000-0002-5349-4265)
- Cristiano de Oliveira Dietrich (ORCID: https://orcid.org/0000-0002-7373-9119)
- Felipe Kalil
Institutions
- Escola Bahiana de Medicina e Saúde Pública (BR)
- Hospital São Rafael (BR)
- Texas Cardiac Arrhythmia (US)
Publication Details
- Journal
- Journal of Cardiac Arrhythmias
- Published
- 2024-11-21
- DOI
- https://doi.org/10.24207/jca.v37i1.3567
- Primary Topic
- Cardiac Arrhythmias and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00