Application of Real-Time Palm Imaging with Nelder–Mead Particle Swarm Optimization/Regression Algorithms for Non-Contact Blood Pressure Detection

In response to the rising prevalence of hypertension due to lifestyle changes, this study introduces a novel approach for non-contact blood pressure (BP) monitoring. Recognizing the "silent killer" nature of hypertension, this research focuses on developing accessible, non-invasive BP measurement methods. This study compares two distinct non-contact BP measurement approaches: one combining the Nelder-Mead simplex method with particle swarm optimization (NM-PSO) and the other using machine learning regression analysis. In the NM-PSO method, a standard webcam captures continuous images of the palm, extracting physiological data through light wave reflection and employing independent component analysis (ICA) to remove noise artifacts. The NM-PSO achieves a verified root mean square error (RMSE) of 2.71 mmHg for systolic blood pressure (SBP) and 3.42 mmHg for diastolic blood pressure (DBP). Alternatively, the regression method derives BP values through machine learning-based regression formulas, resulting in an RMSE of 2.88 mmHg for SBP and 2.60 mmHg for DBP. Both methods enable fast, accurate, and convenient BP measurement within 10 s, suitable for home use. This study demonstrates a cost-effective solution for non-contact BP monitoring and highlights each method's advantages. The NM-PSO approach emphasizes optimization in noise handling, while the regression method leverages formulaic efficiency in BP estimation. These results offer a biomimetic approach that could replace traditional contact-based BP measurement devices, contributing to enhanced accessibility in hypertension management.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2024-11-20
DOI
https://doi.org/10.3390/biomimetics9110713
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Real-Time Palm Imaging with Nelder–Mead Particle Swarm Optimization/Regression Algorithms for Non-Contact Blood Pressure Detection

Te‐Jen Su, Shih-Ming Wang, Yuheng Fei, Wei-Hong Lin et al.
Biomimetics
Non-Invasive Vital Sign Monitoring
article

Application of Real-Time Palm Imaging with Nelder–Mead Particle Swarm Optimization/Regression Algorithms for Non-Contact Blood Pressure Detection

Te‐Jen Su, Shih-Ming Wang, Yuheng Fei, Wei-Hong Lin, Qian-Yi Zhuang, Wenbo Yang, Ya-Chung Hung
article en

Abstract

In response to the rising prevalence of hypertension due to lifestyle changes, this study introduces a novel approach for non-contact blood pressure (BP) monitoring. Recognizing the "silent killer" nature of hypertension, this research focuses on developing accessible, non-invasive BP measurement methods. This study compares two distinct non-contact BP measurement approaches: one combining the Nelder-Mead simplex method with particle swarm optimization (NM-PSO) and the other using machine learning regression analysis. In the NM-PSO method, a standard webcam captures continuous images of the palm, extracting physiological data through light wave reflection and employing independent component analysis (ICA) to remove noise artifacts. The NM-PSO achieves a verified root mean square error (RMSE) of 2.71 mmHg for systolic blood pressure (SBP) and 3.42 mmHg for diastolic blood pressure (DBP). Alternatively, the regression method derives BP values through machine learning-based regression formulas, resulting in an RMSE of 2.88 mmHg for SBP and 2.60 mmHg for DBP. Both methods enable fast, accurate, and convenient BP measurement within 10 s, suitable for home use. This study demonstrates a cost-effective solution for non-contact BP monitoring and highlights each method's advantages. The NM-PSO approach emphasizes optimization in noise handling, while the regression method leverages formulaic efficiency in BP estimation. These results offer a biomimetic approach that could replace traditional contact-based BP measurement devices, contributing to enhanced accessibility in hypertension management.

BiomimeticsVol. 9(11)
National Kaohsiung University of Science and Technology (TW), Cheng Shiu University (TW)
National Science and Technology Council
Openalex Percentile: Top 81%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.