Catheter‐Based Renal Denervation for Resistant Arterial Hypertension: 10‐Year Real‐World Follow‐Up Data

This analysis of real-world data examines the efficacy, safety, and long-term outcomes of renal denervation in hypertensive patients for up to 10 years. Sixty-five consecutive patients underwent renal denervation (RDN) (single operator) for uncontrolled resistant hypertension. Efficacy was defined as the interindividual change of office (OBPM) and ambulatory blood pressure monitoring (ABPM) at 1, 6, 12 months, 2-4 and 5-10 years after RDN. Medication changes, renal function, and device generation disparities were analyzed. Of these patients, 42 received RDN with a first-generation device, while 23 underwent the procedure with a second-generation device. Baseline demographics included a predominantly male cohort (57.6%) with an average age of 60.3 years. The mean number of medications at baseline was 4.3. OBPM at baseline was 169.0/87.4 mmHg, and ABPM at baseline was 153.4/88.4 mmHg. Post-procedure, significant reductions in systolic blood pressure (SBP) were observed in both OBPM and ABPM at 1 month (OBPM 147.9/82.8 mmHg; ABPM 141.3/83.0 mmHg [SBP, p < 0.001]), sustained up to 10 years (OBPM 153.1/84.3 mmHg; ABPM 138/80.1 mmHg [SBP, p < 0.001]). After 1 year around half of patients had a controlled OBPM and 24 h ABPM < 135/85 mmHg, which was associated with a higher number of ablation spots (31.5±14.8 vs. 15.5 ± 6.5, p = 0.002) and occurred more often when treated with a second-generation device (2 [12.5%] vs. 7 [77.8%], p = 0.002). Renal function displayed a minor physiological decline over 5-10 years. No major complication occurred. Renal denervation demonstrated sustained significant reductions in systolic OBPM and ABPM up to 10 years post-procedure. Controlled blood pressure at 1 year was associated with a higher number of mean ablated spots and the use of a second-generation device. The procedure exhibited a favorable safety profile, indicating its viability in managing hypertension without significant renal function compromise.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Hypertension
Published
2024-11-20
DOI
https://doi.org/10.1111/jch.14931
Citations
3
Primary Topic
Blood Pressure and Hypertension Studies
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Catheter‐Based Renal Denervation for Resistant Arterial Hypertension: 10‐Year Real‐World Follow‐Up Data

K. Bermpeis, Matthias Verbesselt, Dario Tino Bertolone, Sofie Brouwers et al.
3 citations
Journal of Clinical Hypertension
Blood Pressure and Hypertension Studies
1.21
article

Catheter‐Based Renal Denervation for Resistant Arterial Hypertension: 10‐Year Real‐World Follow‐Up Data

K. Bermpeis, Matthias Verbesselt, Dario Tino Bertolone, Sofie Brouwers, Lucio Addeo, Giulia Botti, Michele Mattia Viscusi, Chiara Valeriano, Marta Belmonte, Eric Wyffels
article en
3 citations

Abstract

This analysis of real-world data examines the efficacy, safety, and long-term outcomes of renal denervation in hypertensive patients for up to 10 years. Sixty-five consecutive patients underwent renal denervation (RDN) (single operator) for uncontrolled resistant hypertension. Efficacy was defined as the interindividual change of office (OBPM) and ambulatory blood pressure monitoring (ABPM) at 1, 6, 12 months, 2-4 and 5-10 years after RDN. Medication changes, renal function, and device generation disparities were analyzed. Of these patients, 42 received RDN with a first-generation device, while 23 underwent the procedure with a second-generation device. Baseline demographics included a predominantly male cohort (57.6%) with an average age of 60.3 years. The mean number of medications at baseline was 4.3. OBPM at baseline was 169.0/87.4 mmHg, and ABPM at baseline was 153.4/88.4 mmHg. Post-procedure, significant reductions in systolic blood pressure (SBP) were observed in both OBPM and ABPM at 1 month (OBPM 147.9/82.8 mmHg; ABPM 141.3/83.0 mmHg [SBP, p < 0.001]), sustained up to 10 years (OBPM 153.1/84.3 mmHg; ABPM 138/80.1 mmHg [SBP, p < 0.001]). After 1 year around half of patients had a controlled OBPM and 24 h ABPM < 135/85 mmHg, which was associated with a higher number of ablation spots (31.5±14.8 vs. 15.5 ± 6.5, p = 0.002) and occurred more often when treated with a second-generation device (2 [12.5%] vs. 7 [77.8%], p = 0.002). Renal function displayed a minor physiological decline over 5-10 years. No major complication occurred. Renal denervation demonstrated sustained significant reductions in systolic OBPM and ABPM up to 10 years post-procedure. Controlled blood pressure at 1 year was associated with a higher number of mean ablated spots and the use of a second-generation device. The procedure exhibited a favorable safety profile, indicating its viability in managing hypertension without significant renal function compromise.

Journal of Clinical HypertensionVol. 26(12)
Vrije Universiteit Brussel (BE), Vita-Salute San Raffaele University (IT), Universitair Ziekenhuis Leuven (BE), Onze Lieve Vrouwziekenhuis Hospital (BE), University of Naples Federico II (IT), KU Leuven (BE)
Good health and well-being
Openalex Percentile: Top 17%
Blood Pressure and Hypertension Studies
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.