A Transient Stability Enhanced Andronov-Hopf Oscillator : Analysis and Design

Grid forming control has been widely applied in renewable energy and energy storage systems due to its ability to generate self-synchronous voltage and exhibit superior small-signal stability under weak grid. Andronov-Hopf oscillator (AHO) control is an emerging grid-forming control, while its transient behaviors under grid voltage faults have not been fully explored. Unlike the fixed droop coefficients of droop control, the transient stability of AHO-based converter under grid faults is compromised by the equivalent nonlinear droop coefficients of AHO control. In this paper, a transient stability enhanced Andronov-Hopf oscillator (EAHO) control is proposed. By reconstructing the dynamic equations of traditional AHO control, the monotonically decreasing nonlinear droop coefficients of traditional AHO control are reshaped into monotonically increasing as the voltage magnitude increases. The transient stability features of the droop, AHO, and EAHO control during grid voltage faults are compared and summarized. The theoretical analysis and simulation results show that the transient stability of EAHO control is significantly improved than AHO control.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/ecceeurope62508.2024.10751897
Citations
1
Primary Topic
Nonlinear Dynamics and Pattern Formation
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Transient Stability Enhanced Andronov-Hopf Oscillator : Analysis and Design

Yueyin Wang, Wu Chen, Siyi Luo
1 citations
Nonlinear Dynamics and Pattern Formation
0.35
article

A Transient Stability Enhanced Andronov-Hopf Oscillator : Analysis and Design

Yueyin Wang, Wu Chen, Siyi Luo
article en
1 citations

Abstract

Grid forming control has been widely applied in renewable energy and energy storage systems due to its ability to generate self-synchronous voltage and exhibit superior small-signal stability under weak grid. Andronov-Hopf oscillator (AHO) control is an emerging grid-forming control, while its transient behaviors under grid voltage faults have not been fully explored. Unlike the fixed droop coefficients of droop control, the transient stability of AHO-based converter under grid faults is compromised by the equivalent nonlinear droop coefficients of AHO control. In this paper, a transient stability enhanced Andronov-Hopf oscillator (EAHO) control is proposed. By reconstructing the dynamic equations of traditional AHO control, the monotonically decreasing nonlinear droop coefficients of traditional AHO control are reshaped into monotonically increasing as the voltage magnitude increases. The transient stability features of the droop, AHO, and EAHO control during grid voltage faults are compared and summarized. The theoretical analysis and simulation results show that the transient stability of EAHO control is significantly improved than AHO control.

Southeast University (CN)
Openalex Percentile: Top 36%
Nonlinear Dynamics and Pattern Formation
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Transient Stability Enhanced Andronov-Hopf Oscillator : Analysis and Design — Yueyin Wang, Wu Chen, et al. · (2024) | TGRS Research Map | TGRS