Impact of multiple flexible loads on grid stability for Fast Frequency Reserve

The increasing share of integrated renewable energy sources results in weaker grids and reduced system inertia, posing challenges to grid stability. To address this, fast frequency reserve (FFR) services are being introduced to tackle this problem. Inverter-based loads, with their rapid response, can enhance grid stability by providing FFR services. Therefore, this work aims to investigate the concurrent support provided by various types of flexible loads (FL) (e.g. data centers, charging stations, and hydrogen electrolyzers) under current and future grid conditions. This investigation is conducted through case studies using as a base a 12-bus grid model that incorporates existing frequency containment reserve for disturbances (FCR-D) support provided by hydro units in the Nordic system. The simulation models of introduced FL capture their control loops and main dynamics. The results show that concurrent FFR support of multiple different FLs (without communication with each other) improves frequency response during disturbance in the considered system for the 15% and 30% of wind power plant penetration (WPP). However, with the higher penetration share of 50% of WPP, the current FFR response characteristics with existing FCR-D cannot maintain stable system operation once FFR is deactivated.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/ecceeurope62508.2024.10751971
Citations
2
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of multiple flexible loads on grid stability for Fast Frequency Reserve

Niko Nevaranta, Anna Tupitsina, Jero Ahola, Tuomo Lindh et al.
2 citations
Microgrid Control and Optimization
0.66
article

Impact of multiple flexible loads on grid stability for Fast Frequency Reserve

Niko Nevaranta, Anna Tupitsina, Jero Ahola, Tuomo Lindh, Marek Rehtla
article en
2 citations

Abstract

The increasing share of integrated renewable energy sources results in weaker grids and reduced system inertia, posing challenges to grid stability. To address this, fast frequency reserve (FFR) services are being introduced to tackle this problem. Inverter-based loads, with their rapid response, can enhance grid stability by providing FFR services. Therefore, this work aims to investigate the concurrent support provided by various types of flexible loads (FL) (e.g. data centers, charging stations, and hydrogen electrolyzers) under current and future grid conditions. This investigation is conducted through case studies using as a base a 12-bus grid model that incorporates existing frequency containment reserve for disturbances (FCR-D) support provided by hydro units in the Nordic system. The simulation models of introduced FL capture their control loops and main dynamics. The results show that concurrent FFR support of multiple different FLs (without communication with each other) improves frequency response during disturbance in the considered system for the 15% and 30% of wind power plant penetration (WPP). However, with the higher penetration share of 50% of WPP, the current FFR response characteristics with existing FCR-D cannot maintain stable system operation once FFR is deactivated.

Lappeenranta-Lahti University of Technology (FI)
Business Finland
Affordable and clean energy
Openalex Percentile: Top 29%
Microgrid Control and Optimization
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.