Frequency Characteristics Analysis of Partial Discharge Ultrasonic Signals in Generator Stator Windings

In recent years, due to the uneven distribution of electric field at the end of stator winding, ventilation slot and slot gap, stator rod insulation corrosion breakdown accidents often occur, which seriously affects the normal operation of generator and the stability of power grid. Due to the narrow space inside the generator, it is impossible to realize the internal installation of the traditional piezoelectric ceramic ultrasonic sensor, so it is proposed to implant the sensor into the notch block between the stator winding of the generator to achieve accurate detection. The research is divided into two steps, firstly, the time-frequency characteristics of the stator winding partial discharge ultrasonic signal are studied, and secondly, the design of the implantable ultrasonic sensor is carried out on the basis of the previous step. This paper is the first step of the study. The partial discharge experiment of stator winding slot of large generator is carried out. The ultrasonic signal generated during partial discharge is measured and the frequency characteristic of the ultrasonic signal is analyzed. The results show that when the insulation structure of the stator winding of the generator is not damaged obviously, the winding has internal discharge, and the characteristic frequency of the ultrasonic signal is 80kHz100kHz. When the low-resistance anti-corona layer is damaged, the ultrasonic signal frequency generated by the corona discharge at the notch is 20kHz-50kHz, and the signal will be superimposed with the 80kHz-100kHz high-frequency signal generated by the internal structure discharge of the winding. The research in this paper provides a practical basis for the diagnosis of generator stator winding insulation state based on partial discharge ultrasonic signal analysis.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750652
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency Characteristics Analysis of Partial Discharge Ultrasonic Signals in Generator Stator Windings

Lisheng Zhong, Ming Wu, Zhihui Xie, Jinghui Gao et al.
Advanced Sensor and Control Systems
article

Frequency Characteristics Analysis of Partial Discharge Ultrasonic Signals in Generator Stator Windings

Lisheng Zhong, Ming Wu, Zhihui Xie, Jinghui Gao, Jin Zhou, Yue Zhang, Hongxin Gong, Haohao Cai, Zongqiang Ren
article en

Abstract

In recent years, due to the uneven distribution of electric field at the end of stator winding, ventilation slot and slot gap, stator rod insulation corrosion breakdown accidents often occur, which seriously affects the normal operation of generator and the stability of power grid. Due to the narrow space inside the generator, it is impossible to realize the internal installation of the traditional piezoelectric ceramic ultrasonic sensor, so it is proposed to implant the sensor into the notch block between the stator winding of the generator to achieve accurate detection. The research is divided into two steps, firstly, the time-frequency characteristics of the stator winding partial discharge ultrasonic signal are studied, and secondly, the design of the implantable ultrasonic sensor is carried out on the basis of the previous step. This paper is the first step of the study. The partial discharge experiment of stator winding slot of large generator is carried out. The ultrasonic signal generated during partial discharge is measured and the frequency characteristic of the ultrasonic signal is analyzed. The results show that when the insulation structure of the stator winding of the generator is not damaged obviously, the winding has internal discharge, and the characteristic frequency of the ultrasonic signal is 80kHz100kHz. When the low-resistance anti-corona layer is damaged, the ultrasonic signal frequency generated by the corona discharge at the notch is 20kHz-50kHz, and the signal will be superimposed with the 80kHz-100kHz high-frequency signal generated by the internal structure discharge of the winding. The research in this paper provides a practical basis for the diagnosis of generator stator winding insulation state based on partial discharge ultrasonic signal analysis.

Dongfang Electric Corporation (China) (CN), State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 75%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.