Analysis of PWM Voltage Detection Delay for Current Source Type Electric Motor Emulator

This paper focuses on input voltage detection for an electric motor emulator (EME), which imitates various motor operations accurately. The EME has to detect the PWM voltage of an inverter under test (IUT) as the input voltage of the EME. The delay in the PWM voltage detection reduces the emulation accuracy. This paper reveals the relationship between the cutoff frequency of a low-pass filter (LPF) for voltage detection and the current control bandwidth of both the IUT and the EME. The analysis result mentions that a low cutoff frequency, such as 1 kHz, is acceptable under the current control bandwidth of 100 Hz in the IUT. In addition, the cutoff frequency of the LPF should be set to a frequency larger than eight times the current control bandwidth of the IUT to keep the transient response in any conditions. Furthermore, it is verified that the phase lead compensation keeps the current response when the cutoff frequency and the current control bandwidth of the IUT are close.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/ecceeurope62508.2024.10751939
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of PWM Voltage Detection Delay for Current Source Type Electric Motor Emulator

Jun‐ichi Itoh, Hiroki Watanabe, Gensui Tanaka
Engineering Applied Research
article

Analysis of PWM Voltage Detection Delay for Current Source Type Electric Motor Emulator

Jun‐ichi Itoh, Hiroki Watanabe, Gensui Tanaka
article en

Abstract

This paper focuses on input voltage detection for an electric motor emulator (EME), which imitates various motor operations accurately. The EME has to detect the PWM voltage of an inverter under test (IUT) as the input voltage of the EME. The delay in the PWM voltage detection reduces the emulation accuracy. This paper reveals the relationship between the cutoff frequency of a low-pass filter (LPF) for voltage detection and the current control bandwidth of both the IUT and the EME. The analysis result mentions that a low cutoff frequency, such as 1 kHz, is acceptable under the current control bandwidth of 100 Hz in the IUT. In addition, the cutoff frequency of the LPF should be set to a frequency larger than eight times the current control bandwidth of the IUT to keep the transient response in any conditions. Furthermore, it is verified that the phase lead compensation keeps the current response when the cutoff frequency and the current control bandwidth of the IUT are close.

Nagaoka University of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 76%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.