Investigation of Dielectric Response in a 22/0.4 kV Distribution Transformer: Effects of Moisture Content

Transformers play a crucial role in power systems, ensuring efficient energy transmission and distribution. This research focuses on a 22/0.4 kV transformer decommissioned after over 20 years of service. The study involves draining the transformer oil completely and refilling it with oil characterized by known moisture content and breakdown voltage levels until reaching normal operating conditions. The objective is to study the effects of increased moisture content on the dielectric response within the actual structure of the transformer. Diagnostic measurement techniques, including Frequency Domain Spectroscopy (FDS) and Polarization Depolarization Current (PDC), are utilized to evaluate the insulation condition of the transformer. FDS provides information on the dielectric response over a wide frequency range, while PDC assesses the polarization and depolarization behavior of the insulation material. These techniques offer valuable information on the ageing and moisture content of the insulation. The experimental results will be presented and discussed in this paper.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750614
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Dielectric Response in a 22/0.4 kV Distribution Transformer: Effects of Moisture Content

Dusit Suksawat, Norasage Pattanadech, Komin Chumpiboon, Siwakorn Jeenmuang et al.
Power Transformer Diagnostics and Insulation
article

Investigation of Dielectric Response in a 22/0.4 kV Distribution Transformer: Effects of Moisture Content

Dusit Suksawat, Norasage Pattanadech, Komin Chumpiboon, Siwakorn Jeenmuang, Chanin Bunlaksananusorn, Danaiwat Daengdee
article en

Abstract

Transformers play a crucial role in power systems, ensuring efficient energy transmission and distribution. This research focuses on a 22/0.4 kV transformer decommissioned after over 20 years of service. The study involves draining the transformer oil completely and refilling it with oil characterized by known moisture content and breakdown voltage levels until reaching normal operating conditions. The objective is to study the effects of increased moisture content on the dielectric response within the actual structure of the transformer. Diagnostic measurement techniques, including Frequency Domain Spectroscopy (FDS) and Polarization Depolarization Current (PDC), are utilized to evaluate the insulation condition of the transformer. FDS provides information on the dielectric response over a wide frequency range, while PDC assesses the polarization and depolarization behavior of the insulation material. These techniques offer valuable information on the ageing and moisture content of the insulation. The experimental results will be presented and discussed in this paper.

King Mongkut's Institute of Technology Ladkrabang (TH)
Openalex Percentile: Top 81%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of Dielectric Response in a 22/0.4 kV Distribution Transformer: Effects of Moisture Content — Dusit Suksawat, Norasage Pattanadech, et al. · (2024) | TGRS Research Map | TGRS