The Behavior of Dissolved Gas in Difference Liquid Insulation With ZnO Under Thermal Ageing Condition

Mineral oil is a commercial product that has been widely used as a dielectric liquid in transformers. However, alternative liquids have been developed to gradually replace mineral oil because of some better liquid insulating properties in the point of safety aspect and environmentally friendly. This paper represented the behavior of Dissolved Gas in different types of liquid insulations mixed with nanoparticles under thermal aging conditions. Various types of liquid insulation including mineral oil, natural ester, and palm oil added with a 0.03% concentration of zinc oxide (ZnO) and sorbitan mono-oleate surfactant (Span 80) underwent thermal stress aging at 90, 110, 130, and 150 degrees Celsius with 200 mbar for 72 hours in a vacuum oven. Then, the concentration of dissolved gas in the stressed samples was investigated by the Dissolved Gas Analysis (DGA) technique. From the test results, it was discovered that distinct liquid insulations and aging temperatures produced diverse dissolved gas generation behaviors. Besides, the dielectric liquid with Nanofluids or Nanofluids mixed with span 80 seems to have no different dissolved gas generation behaviors.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750759
Primary Topic
Aerogels and thermal insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Behavior of Dissolved Gas in Difference Liquid Insulation With ZnO Under Thermal Ageing Condition

Norasage Pattanadech, Korraya Jongvilaikasem, Naratip Vittayakorn, Chanin Bunlaksananusorn
Aerogels and thermal insulation
article

The Behavior of Dissolved Gas in Difference Liquid Insulation With ZnO Under Thermal Ageing Condition

Norasage Pattanadech, Korraya Jongvilaikasem, Naratip Vittayakorn, Chanin Bunlaksananusorn
article en

Abstract

Mineral oil is a commercial product that has been widely used as a dielectric liquid in transformers. However, alternative liquids have been developed to gradually replace mineral oil because of some better liquid insulating properties in the point of safety aspect and environmentally friendly. This paper represented the behavior of Dissolved Gas in different types of liquid insulations mixed with nanoparticles under thermal aging conditions. Various types of liquid insulation including mineral oil, natural ester, and palm oil added with a 0.03% concentration of zinc oxide (ZnO) and sorbitan mono-oleate surfactant (Span 80) underwent thermal stress aging at 90, 110, 130, and 150 degrees Celsius with 200 mbar for 72 hours in a vacuum oven. Then, the concentration of dissolved gas in the stressed samples was investigated by the Dissolved Gas Analysis (DGA) technique. From the test results, it was discovered that distinct liquid insulations and aging temperatures produced diverse dissolved gas generation behaviors. Besides, the dielectric liquid with Nanofluids or Nanofluids mixed with span 80 seems to have no different dissolved gas generation behaviors.

King Mongkut's Institute of Technology Ladkrabang (TH)
Openalex Percentile: Top 84%
Aerogels and thermal insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Behavior of Dissolved Gas in Difference Liquid Insulation With ZnO Under Thermal Ageing Condition — Norasage Pattanadech, Korraya Jongvilaikasem, et al. · (2024) | TGRS Research Map | TGRS