Dielectric Response Analysis Characteristic of Service-Aged XLPE Cables

The main insulation used in plastic underground cables is cross-linked polyethylene (XLPE). The XLPE underground cable which has been utilized in service for a long time, has experienced various stresses, or so-called TEAM stresses. Consequently, the XLPE insulation will be degraded over time and lead to insulation properties degradation. This paper represents the dielectric response analysis technique for characterizing the insulation condition of the service-aged XLPE medium voltage underground cable. The dielectric response analysis was performed on the 22 kV XLPE underground cables that have been in service for more than 10 years and were directly buried. The dielectric response analysis measurement consists of a combination of polarization and depolarization current (PDC) measurement in the time-domain and frequency-domain spectroscopy (FDS) measurement. After that, test results were analyzed to evaluate the insulation condition and compare it to the new 22 kV underground cable. The analyzed dielectric response analysis test results will be reported in this paper.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750766
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dielectric Response Analysis Characteristic of Service-Aged XLPE Cables

Patt Udomluksananon, Norasage Pattanadech, Siwakorn Jeenmuang, Theerayod Wiangtong et al.
High voltage insulation and dielectric phenomena
article

Dielectric Response Analysis Characteristic of Service-Aged XLPE Cables

Patt Udomluksananon, Norasage Pattanadech, Siwakorn Jeenmuang, Theerayod Wiangtong, Patchara Thongkong, Wiboon Promphanich
article en

Abstract

The main insulation used in plastic underground cables is cross-linked polyethylene (XLPE). The XLPE underground cable which has been utilized in service for a long time, has experienced various stresses, or so-called TEAM stresses. Consequently, the XLPE insulation will be degraded over time and lead to insulation properties degradation. This paper represents the dielectric response analysis technique for characterizing the insulation condition of the service-aged XLPE medium voltage underground cable. The dielectric response analysis was performed on the 22 kV XLPE underground cables that have been in service for more than 10 years and were directly buried. The dielectric response analysis measurement consists of a combination of polarization and depolarization current (PDC) measurement in the time-domain and frequency-domain spectroscopy (FDS) measurement. After that, test results were analyzed to evaluate the insulation condition and compare it to the new 22 kV underground cable. The analyzed dielectric response analysis test results will be reported in this paper.

King Mongkut's Institute of Technology Ladkrabang (TH)
King Mongkut's Institute of Technology Ladkrabang
Openalex Percentile: Top 87%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dielectric Response Analysis Characteristic of Service-Aged XLPE Cables — Patt Udomluksananon, Norasage Pattanadech, et al. · (2024) | TGRS Research Map | TGRS