Generic Approach to Reference Signal Generation for Active Power Filters

A generic approach to the generation of reference signals for active power filters (APFs) is proposed. The focus is on the implementation of frequency-selective operation strategies based on Fourier series. This is premised on the ideal extraction of the frequency components of the system’s voltages and currents, as well as the ideal utlization of the computed reference signals in the physical control system. The approach allows for arbitrary distortions and imbalances with respect to both, line voltages and load characteristics. Specific algorithms are showcased to demonstrate how nearly any stationary system behavior can be replicated by the active power filter applying a suitable operation strategy. The effectiveness of the proposed approach is validated by comprehensive simulation results.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/ecceeurope62508.2024.10752042
Citations
1
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generic Approach to Reference Signal Generation for Active Power Filters

Christoph M. Hackl, Marek Gałek, Daniela Fehrenbach, Christoph Göttsberger
1 citations
Power Quality and Harmonics
0.21
article

Generic Approach to Reference Signal Generation for Active Power Filters

Christoph M. Hackl, Marek Gałek, Daniela Fehrenbach, Christoph Göttsberger
article en
1 citations

Abstract

A generic approach to the generation of reference signals for active power filters (APFs) is proposed. The focus is on the implementation of frequency-selective operation strategies based on Fourier series. This is premised on the ideal extraction of the frequency components of the system’s voltages and currents, as well as the ideal utlization of the computed reference signals in the physical control system. The approach allows for arbitrary distortions and imbalances with respect to both, line voltages and load characteristics. Specific algorithms are showcased to demonstrate how nearly any stationary system behavior can be replicated by the active power filter applying a suitable operation strategy. The effectiveness of the proposed approach is validated by comprehensive simulation results.

Munich University of Applied Sciences (DE)
Ministry of Education, Siemens
Affordable and clean energy
Openalex Percentile: Top 46%
Power Quality and Harmonics
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.