Improvement of Lightning Conductors to Prevent Creeping Discharge

This research is a test of a lightning conductor that can prevent or reduce the distance from lightning current jumps between the lightning conductor and nearby metal. The lightning conductor must have durable insulation to protect against lightning current jumps to a certain extent. But if the separation distance (s) cannot be maintained, the potential must be coordinated with the lightning conductor to prevent the occurrence of metal arcs. This research will test the ability to protect the separation distance, s = 50 cm. A copper lightning conductor has a cross-sectional area of 50 sq.mm. and the thickness of the electrical insulation is an important part in protecting against a voltage of 600. kV. If there is no insulation to protect the voltage at 600 kV, the ability to jump the lightning current will be at a distance of 50 m. The KHV cable is important for intelligent buildings that have lightning protection systems. It can isolate electrical and electronic equipment and external lightning protection.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750768
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improvement of Lightning Conductors to Prevent Creeping Discharge

Boonsak Kiatjaroonlert, Pathorn Sirachansawang, Techatat Buranaaudsawakul, P. Apiratikul et al.
1 links
High voltage insulation and dielectric phenomena
article

Improvement of Lightning Conductors to Prevent Creeping Discharge

Boonsak Kiatjaroonlert, Pathorn Sirachansawang, Techatat Buranaaudsawakul, P. Apiratikul, Wiroj Tangtheerajaroonwong, Atthapol Ngaopitakkul, Surachai Phommeepun
article en

Abstract

This research is a test of a lightning conductor that can prevent or reduce the distance from lightning current jumps between the lightning conductor and nearby metal. The lightning conductor must have durable insulation to protect against lightning current jumps to a certain extent. But if the separation distance (s) cannot be maintained, the potential must be coordinated with the lightning conductor to prevent the occurrence of metal arcs. This research will test the ability to protect the separation distance, s = 50 cm. A copper lightning conductor has a cross-sectional area of 50 sq.mm. and the thickness of the electrical insulation is an important part in protecting against a voltage of 600. kV. If there is no insulation to protect the voltage at 600 kV, the ability to jump the lightning current will be at a distance of 50 m. The KHV cable is important for intelligent buildings that have lightning protection systems. It can isolate electrical and electronic equipment and external lightning protection.

PTT Public Company Limited (Thailand) (TH), Rajamangala University of Technology (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
National Science Foundation
Climate action
Openalex Percentile: Top 87%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improvement of Lightning Conductors to Prevent Creeping Discharge — Boonsak Kiatjaroonlert, Pathorn Sirachansawang, et al. · (2024) | TGRS Research Map | TGRS