Partial Discharge Characteristics of a Defective MV XLPE Cable

This paper presents the partial discharge (PD) test on a 22 kV underground cable having a simulated defect within the XLPE insulation. The defects were simulated using the nail, as the drill bits with a different drill diameter. The defect was created into the XLPE insulation layers of the underground cable. Besides, both end sides of the cable were electric field controlled. To simulate the defects for the experiment, the jacket in the middle of the cable was partially trimmed out, and the drill bits was driven through the insulation screen to the insulation layer. The diameter of the drill bits was controlled for each experiment. The PD experiment was conducted using high frequency current transformer (HFCT) sensor as an unconventional PD detection instrument. From analyzing the PD test results, a defect in the XLPE insulation causes vividly the PD inside the XLPE insulation. Consequently, the insulation gradually deteriorates undergoing the PD events. Moreover, the PD test results indicate that the larger diameter of the nail tip radius results in a higher PD magnitude than that generated by a smaller diameter.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750726
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Partial Discharge Characteristics of a Defective MV XLPE Cable

Salah-ddine Krit, Norasage Pattanadech, Siwakorn Jeenmuang, Sawai Pongswatd et al.
High voltage insulation and dielectric phenomena
article

Partial Discharge Characteristics of a Defective MV XLPE Cable

Salah-ddine Krit, Norasage Pattanadech, Siwakorn Jeenmuang, Sawai Pongswatd, Woraphat Ekasittiphong, Worasak Tangthanam
article en

Abstract

This paper presents the partial discharge (PD) test on a 22 kV underground cable having a simulated defect within the XLPE insulation. The defects were simulated using the nail, as the drill bits with a different drill diameter. The defect was created into the XLPE insulation layers of the underground cable. Besides, both end sides of the cable were electric field controlled. To simulate the defects for the experiment, the jacket in the middle of the cable was partially trimmed out, and the drill bits was driven through the insulation screen to the insulation layer. The diameter of the drill bits was controlled for each experiment. The PD experiment was conducted using high frequency current transformer (HFCT) sensor as an unconventional PD detection instrument. From analyzing the PD test results, a defect in the XLPE insulation causes vividly the PD inside the XLPE insulation. Consequently, the insulation gradually deteriorates undergoing the PD events. Moreover, the PD test results indicate that the larger diameter of the nail tip radius results in a higher PD magnitude than that generated by a smaller diameter.

King Mongkut's Institute of Technology Ladkrabang (TH)
Affordable and clean energy
Openalex Percentile: Top 87%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Partial Discharge Characteristics of a Defective MV XLPE Cable — Salah-ddine Krit, Norasage Pattanadech, et al. · (2024) | TGRS Research Map | TGRS