Multi-Parameter Detection of Defects in HV Cable Buffer Layer Based on Gas, Temperature, and Pressure

High voltage cable is an important part of the power system. Water ingress into the buffer layer and poor contact with the aluminum sheath in high voltage cables can cause ablation defects and local overheating. Power accidents due to buffer layer ablation have occurred frequently in recent years. However, there is a lack of effective diagnostic methods for buffer layer ablation defects. To address the above problems, a multi-parameter detection method for ablation defects in the buffer layer of high-voltage cables based on gas, temperature, and pressure analysis is proposed. The volume fraction, temperature, and pressure of the characteristic gases C<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf>, C<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf>, CO, and H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> are used as the characteristic parameters to characterize the ablation defects of the buffer layer. Infrared spectroscopy was used to analyze the volume fraction of the characteristic gases, a thermocouple sensor was used to measure the temperature, and a piezoelectric sensor was used to measure the pressure. Simulated ablation analysis experiments and actual cable detection verified the method's validity. The results show that with the increase of ablation time, the characteristic gas volume fraction, temperature, and pressure all show an increasing trend. The characteristic gas volume fraction, temperature and pressure in the buffer layer of high-voltage cables with ablation defects in the field are higher than those without ablation. The characteristic gases, temperature, and pressure can be used to characterize the buffer layer ablation defects and to diagnose these defects. It is expected to be a new diagnostic method for buffer layer ablation defects in high voltage cables. It can support the early warning of power accidents and improve the safety of high-voltage cable operation.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750559
Citations
1
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Parameter Detection of Defects in HV Cable Buffer Layer Based on Gas, Temperature, and Pressure

Houqing Chen, Chongzhi Liu, Zhigang Ren, Jian Gao et al.
1 citations
Power Line Inspection Robots
0.21
article

Multi-Parameter Detection of Defects in HV Cable Buffer Layer Based on Gas, Temperature, and Pressure

Houqing Chen, Chongzhi Liu, Zhigang Ren, Jian Gao, Tonghai Wu, Zeyu Zhang, Jianying Li, Xiaojun Tang, Xiaoshan Li
article en
1 citations

Abstract

High voltage cable is an important part of the power system. Water ingress into the buffer layer and poor contact with the aluminum sheath in high voltage cables can cause ablation defects and local overheating. Power accidents due to buffer layer ablation have occurred frequently in recent years. However, there is a lack of effective diagnostic methods for buffer layer ablation defects. To address the above problems, a multi-parameter detection method for ablation defects in the buffer layer of high-voltage cables based on gas, temperature, and pressure analysis is proposed. The volume fraction, temperature, and pressure of the characteristic gases C<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</inf>, C<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</inf>, CO, and H<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> are used as the characteristic parameters to characterize the ablation defects of the buffer layer. Infrared spectroscopy was used to analyze the volume fraction of the characteristic gases, a thermocouple sensor was used to measure the temperature, and a piezoelectric sensor was used to measure the pressure. Simulated ablation analysis experiments and actual cable detection verified the method's validity. The results show that with the increase of ablation time, the characteristic gas volume fraction, temperature, and pressure all show an increasing trend. The characteristic gas volume fraction, temperature and pressure in the buffer layer of high-voltage cables with ablation defects in the field are higher than those without ablation. The characteristic gases, temperature, and pressure can be used to characterize the buffer layer ablation defects and to diagnose these defects. It is expected to be a new diagnostic method for buffer layer ablation defects in high voltage cables. It can support the early warning of power accidents and improve the safety of high-voltage cable operation.

Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 50%
Power Line Inspection Robots
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.