Experience in Partial Discharge Investigation of a 155 MVA Air-Cooled Generator

This paper presents the Partial Discharge (PD) and Polarization and Depolarization Current (PDC) investigation for a 155 MVA air-cooled generator. The visual inspection of the stator winding insulation was carried out during the annual preventive maintenance. Several defects in the area of the end winding stator were evidenced. Thereafter, the refurbishment of these problems was performed to improve the stator winding insulation condition, and the offline PD & PDC test was conducted accordingly. Besides, the online PD was continuously monitored, through capacitive PD sensors which have been installed on the terminal of the generator two units per phase. The operating conditions during online PD measurement were also recorded. In this paper, the results from both offline and online PD measurements were presented.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750703
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experience in Partial Discharge Investigation of a 155 MVA Air-Cooled Generator

Pittaya Pannil, Norasage Pattanadech, Komin Chumpiboon, Siwakorn Jeenmuang et al.
Vacuum and Plasma Arcs
article

Experience in Partial Discharge Investigation of a 155 MVA Air-Cooled Generator

Pittaya Pannil, Norasage Pattanadech, Komin Chumpiboon, Siwakorn Jeenmuang, Tehneht Worthong, Khomsan Pathanrat
article en

Abstract

This paper presents the Partial Discharge (PD) and Polarization and Depolarization Current (PDC) investigation for a 155 MVA air-cooled generator. The visual inspection of the stator winding insulation was carried out during the annual preventive maintenance. Several defects in the area of the end winding stator were evidenced. Thereafter, the refurbishment of these problems was performed to improve the stator winding insulation condition, and the offline PD & PDC test was conducted accordingly. Besides, the online PD was continuously monitored, through capacitive PD sensors which have been installed on the terminal of the generator two units per phase. The operating conditions during online PD measurement were also recorded. In this paper, the results from both offline and online PD measurements were presented.

PTT Public Company Limited (Thailand) (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Affordable and clean energy
Openalex Percentile: Top 81%
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experience in Partial Discharge Investigation of a 155 MVA Air-Cooled Generator — Pittaya Pannil, Norasage Pattanadech, et al. · (2024) | TGRS Research Map | TGRS