Effect of Longtime Sheath Current on Insulation Screen of 115kV XLPE Underground Cable

Due to the need to extend the life of underground cables that are universally installed and used in power plants in Thailand, The life assessment must be concerned with advanced techniques, both chemical and physical, exactly. The components that needed to be analyzed were divided into two main groups: the insulation and physical systems. One of the most requisites is pyrolysis. Pyrolysis can occur in the underground cable system with many factors, for instance, the ambient temperature, overload, loss of connector, and longtime sheath current. Thus, this paper described the effect of the longtime sheath current on the insulation screen of 115kV XLPE underground power cable. Sheath current that ran into the system for longtime effectively effected to the insulation screen by destroying the structure of chemical properties leading to the short lifetime and getting the high risk to breakdown with the continue use.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750618
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Longtime Sheath Current on Insulation Screen of 115kV XLPE Underground Cable

Patt Udomluksananon, K. Jariyanurat, Norasage Pattanadech, Siwakorn Jeenmuang et al.
Thermal Analysis in Power Transmission
article

Effect of Longtime Sheath Current on Insulation Screen of 115kV XLPE Underground Cable

Patt Udomluksananon, K. Jariyanurat, Norasage Pattanadech, Siwakorn Jeenmuang, Sittipong Kerdmanee, Sakda Lacharochana
article en

Abstract

Due to the need to extend the life of underground cables that are universally installed and used in power plants in Thailand, The life assessment must be concerned with advanced techniques, both chemical and physical, exactly. The components that needed to be analyzed were divided into two main groups: the insulation and physical systems. One of the most requisites is pyrolysis. Pyrolysis can occur in the underground cable system with many factors, for instance, the ambient temperature, overload, loss of connector, and longtime sheath current. Thus, this paper described the effect of the longtime sheath current on the insulation screen of 115kV XLPE underground power cable. Sheath current that ran into the system for longtime effectively effected to the insulation screen by destroying the structure of chemical properties leading to the short lifetime and getting the high risk to breakdown with the continue use.

PTT Public Company Limited (Thailand) (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Affordable and clean energy
Openalex Percentile: Top 75%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Longtime Sheath Current on Insulation Screen of 115kV XLPE Underground Cable — Patt Udomluksananon, K. Jariyanurat, et al. · (2024) | TGRS Research Map | TGRS