The Effect of Surface Leakage Current on Frequency Domain Spectroscopy of 22 kV OIP Bushing

In this paper the dielectric response in frequency domain or frequency domain spectroscopy (FDS) is used to assess the effect of surface leakage current both from high voltage side and ground side on the FDS results of OIP bushings. The test object in this paper is a 22 kV OIP bushing which is out of service. The surface leakage current can be simulated using the copper tape as a bandage around the bushing core in several locations. From the FDS results, several parameters i.e., dissipation factor, capacitance, and capacitance ratio together with frequency scanning of capacitance and dissipation factor from many cases were investigated to get the fundamental knowledge of how to interpret the FDS result of OIP bushing.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750667
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Surface Leakage Current on Frequency Domain Spectroscopy of 22 kV OIP Bushing

Patt Udomluksananon, Warisanan Rojanasunan, Norasage Pattanadech, Komin Chumpiboon et al.
Power Transformer Diagnostics and Insulation
article

The Effect of Surface Leakage Current on Frequency Domain Spectroscopy of 22 kV OIP Bushing

Patt Udomluksananon, Warisanan Rojanasunan, Norasage Pattanadech, Komin Chumpiboon, Siwakorn Jeenmuang, Phop Chancharoensook
article en

Abstract

In this paper the dielectric response in frequency domain or frequency domain spectroscopy (FDS) is used to assess the effect of surface leakage current both from high voltage side and ground side on the FDS results of OIP bushings. The test object in this paper is a 22 kV OIP bushing which is out of service. The surface leakage current can be simulated using the copper tape as a bandage around the bushing core in several locations. From the FDS results, several parameters i.e., dissipation factor, capacitance, and capacitance ratio together with frequency scanning of capacitance and dissipation factor from many cases were investigated to get the fundamental knowledge of how to interpret the FDS result of OIP bushing.

King Mongkut's Institute of Technology Ladkrabang (TH)
Affordable and clean energy
Openalex Percentile: Top 81%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.