The Effect of Insulating Oil Conditions in Transformer Bushing on Dielectric Response Analysis

The bushing is one of the important parts of a transformer. Once the transformer is operated; each transformer part including its bushing starts the degradation mechanism. In some cases, the dielectric strength degradation of the bushing can lead to severe consequences. Thus, the study and diagnosis of the bushing conditions are important. This study aims to investigate the characteristics of the oil-impregnated pressboard bushing under various oil conditions by filling the new mineral oil with a controlled moisture content and letting it reach an equilibrium state to examine the dielectric response of such bushing. To determine the dielectric characteristics of the investigated bushing, A Frequency Domain Spectroscopy (FDS) device was utilized. In the experiment, the dissipation factor, capacitance, and current measurement of the bushing with different water content level were measured. The bushing test object was tested with the frequency range of 1 mHz –1 kHz. The effect of moisture clearly influenced the low-frequency ranges of the FDS. The result will be discussed in the paper.

Authors

Institutions

Publication Details

Published
2024-08-04
DOI
https://doi.org/10.1109/icpadm61663.2024.10750773
Citations
1
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Insulating Oil Conditions in Transformer Bushing on Dielectric Response Analysis

Noppadol Maneerat, Warisanan Rojanasunan, Techatat Buranaaudsawakul, Pittaya Pannil et al.
1 citations
Power Transformer Diagnostics and Insulation
0.21
article

The Effect of Insulating Oil Conditions in Transformer Bushing on Dielectric Response Analysis

Noppadol Maneerat, Warisanan Rojanasunan, Techatat Buranaaudsawakul, Pittaya Pannil, Norasage Pattanadech, Chanatip Srisub
article en
1 citations

Abstract

The bushing is one of the important parts of a transformer. Once the transformer is operated; each transformer part including its bushing starts the degradation mechanism. In some cases, the dielectric strength degradation of the bushing can lead to severe consequences. Thus, the study and diagnosis of the bushing conditions are important. This study aims to investigate the characteristics of the oil-impregnated pressboard bushing under various oil conditions by filling the new mineral oil with a controlled moisture content and letting it reach an equilibrium state to examine the dielectric response of such bushing. To determine the dielectric characteristics of the investigated bushing, A Frequency Domain Spectroscopy (FDS) device was utilized. In the experiment, the dissipation factor, capacitance, and current measurement of the bushing with different water content level were measured. The bushing test object was tested with the frequency range of 1 mHz –1 kHz. The effect of moisture clearly influenced the low-frequency ranges of the FDS. The result will be discussed in the paper.

King Mongkut's Institute of Technology Ladkrabang (TH)
King Mongkut's Institute of Technology Ladkrabang
Openalex Percentile: Top 46%
Power Transformer Diagnostics and Insulation
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effect of Insulating Oil Conditions in Transformer Bushing on Dielectric Response Analysis — Noppadol Maneerat, Warisanan Rojanasunan, et al. · (2024) | TGRS Research Map | TGRS