A Skin-Tone Insensitive, Fully Integrated Smartwatch for Continuous Blood Pressure Measurement

Smartwatches commonly employ photoplethysmography (PPG) sensors for pulse measurement and health index computation, including heart rate (HR) and blood pressure (BP). However, PPG’s susceptibility to skin tone variations presents challenges to accuracy. This study presents a biomedical eddy current sensor (BECS)-based wristwatch that integrates a passive LC tank, inductance-to-digital converter ASIC, and wireless module fully embedded into the case back of the wristwatch. The BECS technology relies on magnetic coupling between the magnetic fields generated by the LC coil and the counteracting magnetic fields induced by the wrist artery, enabling the measurement of resonant frequency variations in response to arterial pulse signals. To enhance pulse measurement sensitivity, the optimal operating resonant frequency was determined by implementing a capacitor array and measuring pulse signals by human measurement to derive personalized design parameters. The proposed BECS-based wristwatch demonstrates pulse signal measurement insensitivity to skin tone compared to PPG-based modalities, as validated among subjects with different Fitzpatrick skin types. Importantly, the personalized BP algorithm was implemented based on HR and modified normalized pulse volume (mNPV), both derived from the measured pulse signals. The BP performance demonstrates the low mean absolute errors (MAEs) of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.18~\pm ~2.61$ </tex-math></inline-formula> mmHg for systolic BP (SBP) and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.64~\pm ~2.57$ </tex-math></inline-formula> mmHg for diastolic BP (DBP) among ten subjects, meeting the Association for the Advancement of Medical Instrumentation (AAMI) standard below <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5~\pm ~8$ </tex-math></inline-formula> mmHg. The generalization of each personalized BP model was further verified through train-test split validation, with all results remaining within AAMI criteria. In conclusion, this study introduces a novel BECS-based wristwatch, highlighting its skin-tone friendliness and accurate BP monitoring, offering a promising alternative to optical modalities, thereby driving future smartwatch innovations.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2024-11-20
DOI
https://doi.org/10.1109/tim.2024.3502829
Citations
4
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Skin-Tone Insensitive, Fully Integrated Smartwatch for Continuous Blood Pressure Measurement

Yen‐Ling Sung, Ting-Wei Wang, Shih-Hua Ni, Chiu-Yun Huang
4 citations
IEEE Transactions on Instrumentation and Measurement
Non-Invasive Vital Sign Monitoring
0.74
article

A Skin-Tone Insensitive, Fully Integrated Smartwatch for Continuous Blood Pressure Measurement

Yen‐Ling Sung, Ting-Wei Wang, Shih-Hua Ni, Chiu-Yun Huang
article en
4 citations

Abstract

Smartwatches commonly employ photoplethysmography (PPG) sensors for pulse measurement and health index computation, including heart rate (HR) and blood pressure (BP). However, PPG’s susceptibility to skin tone variations presents challenges to accuracy. This study presents a biomedical eddy current sensor (BECS)-based wristwatch that integrates a passive LC tank, inductance-to-digital converter ASIC, and wireless module fully embedded into the case back of the wristwatch. The BECS technology relies on magnetic coupling between the magnetic fields generated by the LC coil and the counteracting magnetic fields induced by the wrist artery, enabling the measurement of resonant frequency variations in response to arterial pulse signals. To enhance pulse measurement sensitivity, the optimal operating resonant frequency was determined by implementing a capacitor array and measuring pulse signals by human measurement to derive personalized design parameters. The proposed BECS-based wristwatch demonstrates pulse signal measurement insensitivity to skin tone compared to PPG-based modalities, as validated among subjects with different Fitzpatrick skin types. Importantly, the personalized BP algorithm was implemented based on HR and modified normalized pulse volume (mNPV), both derived from the measured pulse signals. The BP performance demonstrates the low mean absolute errors (MAEs) of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.18~\pm ~2.61$ </tex-math></inline-formula> mmHg for systolic BP (SBP) and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.64~\pm ~2.57$ </tex-math></inline-formula> mmHg for diastolic BP (DBP) among ten subjects, meeting the Association for the Advancement of Medical Instrumentation (AAMI) standard below <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$5~\pm ~8$ </tex-math></inline-formula> mmHg. The generalization of each personalized BP model was further verified through train-test split validation, with all results remaining within AAMI criteria. In conclusion, this study introduces a novel BECS-based wristwatch, highlighting its skin-tone friendliness and accurate BP monitoring, offering a promising alternative to optical modalities, thereby driving future smartwatch innovations.

IEEE Transactions on Instrumentation and MeasurementVol. 74
National Tsing Hua University (TW), Taipei Medical University (TW)
Openalex Percentile: Top 31%
Non-Invasive Vital Sign Monitoring
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.