A Novel Thermo-FET Sensing System for Binary Chemical Solvent Monitoring Applications

This article introduces a new field-effect transistor (FET)-based sensing system designed to monitor charge/polarity changes during the evaporation of microsize water droplets containing polar substances such as ethanol and methanol. The system utilizes a high transconductance interdigital open-gate junction FET (ID-OGJFET) with a sizeable direct-on-channel sensing area (>16 mm2) in direct contact with the liquid droplet. A new electrofluidic package has also been developed to facilitate sample access on the FET chip, which prevents leakage and connects the sensor to readout systems. An experimental procedure is designed to demonstrate the functionality and applicability of this FET platform sensing system for chemical analysis, such as measuring the concentration of ethanol or methanol in water using the evaporation-based sensing mechanism enabled by the ID-OGJFET. Real-time video capture is employed for monitoring and control. The sensor measures ethanol and methanol concentrations ranging from 0% to 100% with steps of 10% EtOH/MetOH in water, utilizing the evaporation-based sensing mechanism and current output of the ID-OGJFET sensor. The minimum meaningful measured concentration is 1% (v/v) for ethanol and 1.49% (v/v) for methanol. The combined uncertainty analysis of methanol’s concentration predictions ranged from 3.29 to 77.91 s. The expanded uncertainty varied from 6.58 to 155.82 s at a 95% confidence level for concentrations from 0% v/v to 100% with 10% intervals. For ethanol, the combined uncertainties ranged from 4.68 to 98.95 s. The expanded uncertainties, calculated with a coverage factor 2, varied from 9.36 to 197.90 s at a 95% confidence level.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2024-11-20
DOI
https://doi.org/10.1109/tim.2024.3502720
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Thermo-FET Sensing System for Binary Chemical Solvent Monitoring Applications

Morteza Ghafar-Zadeh, Sebastian Magierowski, Giancarlo Ayala‐Charca, Abbas Panahi et al.
IEEE Transactions on Instrumentation and Measurement
Analytical Chemistry and Sensors
article

A Novel Thermo-FET Sensing System for Binary Chemical Solvent Monitoring Applications

Morteza Ghafar-Zadeh, Sebastian Magierowski, Giancarlo Ayala‐Charca, Abbas Panahi, Hamed Osouli Tabrizi, Ebrahim Ghafar‐Zadeh, Ahmad Roshanfar, Yasaman Tahernezhad
article en

Abstract

This article introduces a new field-effect transistor (FET)-based sensing system designed to monitor charge/polarity changes during the evaporation of microsize water droplets containing polar substances such as ethanol and methanol. The system utilizes a high transconductance interdigital open-gate junction FET (ID-OGJFET) with a sizeable direct-on-channel sensing area (>16 mm2) in direct contact with the liquid droplet. A new electrofluidic package has also been developed to facilitate sample access on the FET chip, which prevents leakage and connects the sensor to readout systems. An experimental procedure is designed to demonstrate the functionality and applicability of this FET platform sensing system for chemical analysis, such as measuring the concentration of ethanol or methanol in water using the evaporation-based sensing mechanism enabled by the ID-OGJFET. Real-time video capture is employed for monitoring and control. The sensor measures ethanol and methanol concentrations ranging from 0% to 100% with steps of 10% EtOH/MetOH in water, utilizing the evaporation-based sensing mechanism and current output of the ID-OGJFET sensor. The minimum meaningful measured concentration is 1% (v/v) for ethanol and 1.49% (v/v) for methanol. The combined uncertainty analysis of methanol’s concentration predictions ranged from 3.29 to 77.91 s. The expanded uncertainty varied from 6.58 to 155.82 s at a 95% confidence level for concentrations from 0% v/v to 100% with 10% intervals. For ethanol, the combined uncertainties ranged from 4.68 to 98.95 s. The expanded uncertainties, calculated with a coverage factor 2, varied from 9.36 to 197.90 s at a 95% confidence level.

IEEE Transactions on Instrumentation and MeasurementVol. 74
York University (CA)
Mitacs
Openalex Percentile: Top 79%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.