Grid-Forming Control for VSC-HVDC Links Connected to Weak Grids – a Comparison Study to Vector Current Control

Power-synchronization control (PSC) is a previously proposed grid-forming control for grid-connected voltage source converters (VSCs). A prominent feature of the PSC is that the VSC synchronizes with the grid through a transient transfer of power instead of the traditional phase- locked loop (PLL). By such a control strategy, the VSC mimics the dynamic behavior of a synchronous machine. The PSC is particularly useful for VSC-HVDC links connected to a weak grid, or an island system. This paper intends to demonstrate the advantage of the PSC comparing to the traditional vector current controller (VCC) for VSC-HVDC links connected to a weak grid. By a mathematical equivalent modeling of a VSC using either PSC or VCC, the paper shows the inherent difficulty of the VCC when the short circuit ratio (SCR) of the ac grid becomes low, while the PSC can maintain relatively stable operation for a weak grid with a SCR as low as 1.0.

Authors

Institutions

Publication Details

Published
2024-09-02
DOI
https://doi.org/10.1109/ecceeurope62508.2024.10751890
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Grid-Forming Control for VSC-HVDC Links Connected to Weak Grids – a Comparison Study to Vector Current Control

Lidong Zhang
1 citations
HVDC Systems and Fault Protection
0.21
article

Grid-Forming Control for VSC-HVDC Links Connected to Weak Grids – a Comparison Study to Vector Current Control

Lidong Zhang
article en
1 citations

Abstract

Power-synchronization control (PSC) is a previously proposed grid-forming control for grid-connected voltage source converters (VSCs). A prominent feature of the PSC is that the VSC synchronizes with the grid through a transient transfer of power instead of the traditional phase- locked loop (PLL). By such a control strategy, the VSC mimics the dynamic behavior of a synchronous machine. The PSC is particularly useful for VSC-HVDC links connected to a weak grid, or an island system. This paper intends to demonstrate the advantage of the PSC comparing to the traditional vector current controller (VCC) for VSC-HVDC links connected to a weak grid. By a mathematical equivalent modeling of a VSC using either PSC or VCC, the paper shows the inherent difficulty of the VCC when the short circuit ratio (SCR) of the ac grid becomes low, while the PSC can maintain relatively stable operation for a weak grid with a SCR as low as 1.0.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 46%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.