Dual-Band CW Radar System for Vital Signs Detection With Interference Cancellation Method

A novel dual-band continuous-wave (CW) radar system is proposed. The radar is designed for vital signs detection in terms of breathing rate (BR), heart rate (HR), and radar cardiograph (RCG) waveforms. The system operates at two ISM band frequencies: 2.45 and 5.8 GHz. Two five-port receivers are used as IQ demodulators. A newly developed interference cancellation method is proposed. This new method increases the reliability of heartbeat detection by canceling the interfering respiration signal in terms of its fundamental frequency component. This method is first demonstrated in the frequency domain through signal processing and second implemented in the time domain using hardware. High detection accuracy is demonstrated for several experimental scenarios. The measurement results show that the proposed system detects vital signs effectively with a relative error of less than 5% at distances (between the radar and the measured subject) of up to 2.5 m using the frequency-domain method and 1.5 m using the time-domain method.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Microwave Theory and Techniques
Published
2024-11-20
DOI
https://doi.org/10.1109/tmtt.2024.3494546
Citations
3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Band CW Radar System for Vital Signs Detection With Interference Cancellation Method

Souheil Bensmida, Παναγιώτα Κοντού, Dimitris E. Anagnostou, Huan Chang
3 citations
IEEE Transactions on Microwave Theory and Techniques
Non-Invasive Vital Sign Monitoring
0.55
article

Dual-Band CW Radar System for Vital Signs Detection With Interference Cancellation Method

Souheil Bensmida, Παναγιώτα Κοντού, Dimitris E. Anagnostou, Huan Chang
article en
3 citations

Abstract

A novel dual-band continuous-wave (CW) radar system is proposed. The radar is designed for vital signs detection in terms of breathing rate (BR), heart rate (HR), and radar cardiograph (RCG) waveforms. The system operates at two ISM band frequencies: 2.45 and 5.8 GHz. Two five-port receivers are used as IQ demodulators. A newly developed interference cancellation method is proposed. This new method increases the reliability of heartbeat detection by canceling the interfering respiration signal in terms of its fundamental frequency component. This method is first demonstrated in the frequency domain through signal processing and second implemented in the time domain using hardware. High detection accuracy is demonstrated for several experimental scenarios. The measurement results show that the proposed system detects vital signs effectively with a relative error of less than 5% at distances (between the radar and the measured subject) of up to 2.5 m using the frequency-domain method and 1.5 m using the time-domain method.

IEEE Transactions on Microwave Theory and TechniquesVol. 73(6)
Heriot-Watt University (GB), Heriot-Watt University Malaysia (MY)
Openalex Percentile: Top 36%
Non-Invasive Vital Sign Monitoring
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.