Balanced plasmonic-augmented silicon photonic interferometric sensor for biosensing applications

We demonstrate a self-referenced plasmonic augmented photonic Mach-Zehnder interferometer (MZI) for biosensing applications, incorporating a 70 µm long aluminum plasmonic waveguide in both arms of a silicon nitride (Si<sub>3</sub>N<sub>4</sub>) MZI. Experimental results matched well with numerical simulations, showing extinction ratio (ER) values that exceed 55 dB and bulk sensitivity of 2322 nm/RIU. Wavelength stability measurements revealed 5×10<sup>-3</sup> nm thermal dependance for an ambient temperature fluctuation of 1-degree Celsius which is 50 times better than a conventional hybrid plasmo-photonic asymmetric MZI (aMZI) configuration, highlighting the robustness of the proposed balanced sensor scheme to ambient temperature fluctuations. Moreover, the experimental results show that the proposed sensor has a limit of detection up to 2.6 ×10<sup>-6</sup> RIU. Surface sensitivity of the proposed sensing transducer was evaluated through a C-reactive protein (CRP) surface saturation measurements and found equal to 10.45 nm/RIU for protein binding. Our validated simulation model was then benchmarked against a diverse set of target bio-analytes (proteins, viruses, bacteria, fungi) with surface sensitivity values reaching up to 2306 nm/RIU, indicating the sensor's heterogeneous detection capabilities. The presented self-referencing sensor configuration offers a cost-effective yet scalable and highly sensitive approach for multiplexed on-chip detection of diverse target analytes.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-11-20
DOI
https://doi.org/10.1364/oe.533570
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Balanced plasmonic-augmented silicon photonic interferometric sensor for biosensing applications

Laurent Markey, Omkar Bhalerao, D. Tsiokos, Stephan Suckow et al.
Optics Express
Photonic and Optical Devices
article

Balanced plasmonic-augmented silicon photonic interferometric sensor for biosensing applications

Laurent Markey, Omkar Bhalerao, D. Tsiokos, Stephan Suckow, Athanasios Manolis, George Tsekenis, Max C. Lemme, Christia Eleftheriou, Pratyusha Das, Mahmoud A. Elrabiaay
article en

Abstract

We demonstrate a self-referenced plasmonic augmented photonic Mach-Zehnder interferometer (MZI) for biosensing applications, incorporating a 70 µm long aluminum plasmonic waveguide in both arms of a silicon nitride (Si<sub>3</sub>N<sub>4</sub>) MZI. Experimental results matched well with numerical simulations, showing extinction ratio (ER) values that exceed 55 dB and bulk sensitivity of 2322 nm/RIU. Wavelength stability measurements revealed 5×10<sup>-3</sup> nm thermal dependance for an ambient temperature fluctuation of 1-degree Celsius which is 50 times better than a conventional hybrid plasmo-photonic asymmetric MZI (aMZI) configuration, highlighting the robustness of the proposed balanced sensor scheme to ambient temperature fluctuations. Moreover, the experimental results show that the proposed sensor has a limit of detection up to 2.6 ×10<sup>-6</sup> RIU. Surface sensitivity of the proposed sensing transducer was evaluated through a C-reactive protein (CRP) surface saturation measurements and found equal to 10.45 nm/RIU for protein binding. Our validated simulation model was then benchmarked against a diverse set of target bio-analytes (proteins, viruses, bacteria, fungi) with surface sensitivity values reaching up to 2306 nm/RIU, indicating the sensor's heterogeneous detection capabilities. The presented self-referencing sensor configuration offers a cost-effective yet scalable and highly sensitive approach for multiplexed on-chip detection of diverse target analytes.

Optics ExpressVol. 33(11)
Université Bourgogne Europe (FR), RWTH Aachen University (DE)
Agence Nationale de la Recherche, Centre National de la Recherche Scientifique, Horizon 2020 Framework Programme, European Regional Development Fund
Affordable and clean energy
Openalex Percentile: Top 81%
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.