Simulated grating for absolute measuring the transfer function of 300mm aperture Fizeau interferometer

The simulated grating for absolute measuring the transfer function of large-aperture Fizeau interferometer is proposed, combining with the surface and homogeneity absolute measurement data, the simulated grating absolute surface data without aberration can be obtained more accurately to achieve the full aperture transfer function absolute measurement at all spatial frequency. A 300mm aperture Fizeau interferometer experimental results show that the absolute surface errors of the three flats are less than λ/20(PV) and λ/100(RMS), and the homogeneity measurement is better than 1*10<sup>-6</sup>. The optimized transfer function is better than 0.86 at 1 mm<sup>-1</sup> spatial frequency, which is a 10% improvement.

Authors

Institutions

Publication Details

Published
2024-11-20
DOI
https://doi.org/10.1117/12.3035907
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulated grating for absolute measuring the transfer function of 300mm aperture Fizeau interferometer

Jincheng Zhuang, Quanzhao Wang, Xueyuan Li, Sen Han et al.
Optical measurement and interference techniques
article

Simulated grating for absolute measuring the transfer function of 300mm aperture Fizeau interferometer

Jincheng Zhuang, Quanzhao Wang, Xueyuan Li, Sen Han, Yanjun Wang, Bo Zhang, Ying Yang, Songlin Zhuang, Linji Ji, Yuhang Shen, Chengliang Fu, Jiaqi Qin, Liwei Zhang
article en

Abstract

The simulated grating for absolute measuring the transfer function of large-aperture Fizeau interferometer is proposed, combining with the surface and homogeneity absolute measurement data, the simulated grating absolute surface data without aberration can be obtained more accurately to achieve the full aperture transfer function absolute measurement at all spatial frequency. A 300mm aperture Fizeau interferometer experimental results show that the absolute surface errors of the three flats are less than λ/20(PV) and λ/100(RMS), and the homogeneity measurement is better than 1*10<sup>-6</sup>. The optimized transfer function is better than 0.86 at 1 mm<sup>-1</sup> spatial frequency, which is a 10% improvement.

University of Shanghai for Science and Technology (CN)
Climate action
Openalex Percentile: Top 79%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.