Development of matrix technology of linear-angular measurements

Studies of matrix angle meters with a scale diameter of 5 and 23 mm have been carried out. The objective of the research was to assess the possibility of achieving the predicted meteorological parameters at the level of hundredths of an arc second for angle measurements and several nanometers for linear. To do this, work was carried out to stabilize the meters using a heat sink and thermal protection. Angular measurements were carried out on the basis of a goniometer rotary platform with an angle sensor LIR. Linear measurements were carried out on a two-channel stand with two identical matrix displacement meters. In both experiments, 1.3 Megapixel CMOS digital cameras were used as an image analyzer. It is concluded that the random error of the studied matrix meters does not exceed 0.05 arc-sec for angular measurements and 15 nm for measuring displacements.

Authors

Institutions

Publication Details

Published
2024-11-20
DOI
https://doi.org/10.1117/12.3036874
Primary Topic
Optics and Image Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of matrix technology of linear-angular measurements

А. В. Королев, Roman A. Larichev, Yurii V. Filatov, A. Ya. Lukin
Optics and Image Analysis
article

Development of matrix technology of linear-angular measurements

А. В. Королев, Roman A. Larichev, Yurii V. Filatov, A. Ya. Lukin
article en

Abstract

Studies of matrix angle meters with a scale diameter of 5 and 23 mm have been carried out. The objective of the research was to assess the possibility of achieving the predicted meteorological parameters at the level of hundredths of an arc second for angle measurements and several nanometers for linear. To do this, work was carried out to stabilize the meters using a heat sink and thermal protection. Angular measurements were carried out on the basis of a goniometer rotary platform with an angle sensor LIR. Linear measurements were carried out on a two-channel stand with two identical matrix displacement meters. In both experiments, 1.3 Megapixel CMOS digital cameras were used as an image analyzer. It is concluded that the random error of the studied matrix meters does not exceed 0.05 arc-sec for angular measurements and 15 nm for measuring displacements.

Peter the Great St. Petersburg Polytechnic University (RU), Saint Petersburg State Electrotechnical University (RU)
Openalex Percentile: Top 68%
Optics and Image Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.