Hall probe calibration in high-precision magnetic field mapping system of superconducting cyclotron

Abstract Introduction Superconducting cyclotron can generate high-energy proton beams and are mainly used for radiation therapy of tumors and cancers. In the superconducting cyclotron SC200, the maximum magnetic induction intensity can typically reach up to 4.6 T, and the magnetic field accuracy is 1e-4. Hall probes are commonly used tools for measuring high-intensity magnetic fields. Objective Through comprehensive consideration, this study selects the SENIS Low-Noise Teslameter 3MH5 and Hall probe C to measure the magnetic field. When the magnetic field exceeds the range of 2 T, the measurement accuracy of the Hall probe is less than 1e-4, and the Hall probe needs to be calibrated to improve its measurement accuracy. Methods The Hall probes are calibrated using Swiss METROLAB PT2025 nuclear magnetic resonance (NMR) Tesla instrument and 1062 probe. Based on the calibration principle, a calibration system platform was built, test data were collected, and calibration curves were obtained. At the same time, the calibration data were analyzed through cross-validation experiments using the cubic polynomial fitting method. Results The results indicate that the test deviation range is from −0.1 g to 0.1 g, and the measurement accuracy can reach 1e-4. Conclusion In summary, the Hall probe can accurately measure the magnetic field distribution of the superconducting cyclotron. It can provide accurate and important data for the calculation and analysis of particle beam dynamics.

Authors

Institutions

Publication Details

Journal
Nukleonika
Published
2024-11-20
DOI
https://doi.org/10.2478/nuka-2024-0026
Citations
1
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hall probe calibration in high-precision magnetic field mapping system of superconducting cyclotron

Chuqing Cao, Yongming Liu, Xiang-Dong Wang, Manman Xu et al.
1 citations
Nukleonika
Magnetic Field Sensors Techniques
0.21
article

Hall probe calibration in high-precision magnetic field mapping system of superconducting cyclotron

Chuqing Cao, Yongming Liu, Xiang-Dong Wang, Manman Xu, Yonghong Wu, Lin Xi, Yongsheng Su, Yili Fu
article en
1 citations

Abstract

Abstract Introduction Superconducting cyclotron can generate high-energy proton beams and are mainly used for radiation therapy of tumors and cancers. In the superconducting cyclotron SC200, the maximum magnetic induction intensity can typically reach up to 4.6 T, and the magnetic field accuracy is 1e-4. Hall probes are commonly used tools for measuring high-intensity magnetic fields. Objective Through comprehensive consideration, this study selects the SENIS Low-Noise Teslameter 3MH5 and Hall probe C to measure the magnetic field. When the magnetic field exceeds the range of 2 T, the measurement accuracy of the Hall probe is less than 1e-4, and the Hall probe needs to be calibrated to improve its measurement accuracy. Methods The Hall probes are calibrated using Swiss METROLAB PT2025 nuclear magnetic resonance (NMR) Tesla instrument and 1062 probe. Based on the calibration principle, a calibration system platform was built, test data were collected, and calibration curves were obtained. At the same time, the calibration data were analyzed through cross-validation experiments using the cubic polynomial fitting method. Results The results indicate that the test deviation range is from −0.1 g to 0.1 g, and the measurement accuracy can reach 1e-4. Conclusion In summary, the Hall probe can accurately measure the magnetic field distribution of the superconducting cyclotron. It can provide accurate and important data for the calculation and analysis of particle beam dynamics.

NukleonikaVol. 69(4)
Anhui University of Science and Technology (CN), Harbin Institute of Technology (CN), Wuhu Hit Robot Technology Research Institute (CN), Wuhu Institute of Technology (CN), Anhui Polytechnic University (CN)
Affordable and clean energy
Openalex Percentile: Top 46%
Magnetic Field Sensors Techniques
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.