Fabrication of a non-enzymatic photoelectrochemical sensor based on a BiOBr-CuO nanocomposite for detecting Glucose and Tetracycline

In this study, we developed a non-enzymatic photoelectrochemical sensor using a BiOBr-CuO (BiCu) electrode, which was synthesized via solvothermal method. The sensor was designed for the simultaneous detection of glucose and tetracycline. Our study revealed that the BiCu electrode exhibited superior photocurrent generation compared to the individual BiOBr and CuO electrodes, as demonstrated by cyclic voltammetry and amperometric studies. The BiCu electrode's performance has increased due to the formation of a heterojunction between CuO and BiOBr, which modifies the UV–visible DRS spectrum and generates an internal electric field that reduces the recombination of the photogenerated carriers. This enhanced the capability of the sensor to detect both glucose and tetracycline. We successfully applied the proposed photoelectrochemical sensor to detect human blood glucose level. The sensitivity and detection limit for glucose and tetracycline are 0.1342 mAmM −1 cm −2 , 0.014 mM and 1.7234 mAmM −1 cm −2 , 2.0 μM respectively. Thus, the fabricated electrode demonstrated exceptional catalytic activity, high selectivity, good reproducibility, wide linear detection range, low limit of detection,long-term stability, ease of synthesis, good stability and notable selectivity for detecting both glucose and tetracycline This suggests that the BiCu electrode has significant potential as a reliable platform for the detection of glucose and tetracycline. • Results show the bifunctional ability of BiOBr-CuO as a sensor. • BiOBr-CuO electrode excels in simultaneous glucose and tetracycline detection. • Exhibits high sensitivity of 1.15133 mAmM −1 cm −2 and good selectivity (glucose). • Exhibits high sensitivity of 1.7234mAmM −1 cm −2 and good selectivity (tetracycline).

Authors

Institutions

Publication Details

Journal
Sensors International
Published
2024-11-20
DOI
https://doi.org/10.1016/j.sintl.2024.100310
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of a non-enzymatic photoelectrochemical sensor based on a BiOBr-CuO nanocomposite for detecting Glucose and Tetracycline

J. Madhavan, Davis Varghese, Muthupandian Saravanan, S. Muthupandi et al.
4 citations
Sensors International
Electrochemical sensors and biosensors
0.83
article

Fabrication of a non-enzymatic photoelectrochemical sensor based on a BiOBr-CuO nanocomposite for detecting Glucose and Tetracycline

J. Madhavan, Davis Varghese, Muthupandian Saravanan, S. Muthupandi, P. Joselene Suzan Jennifer, M. Victor Antony Raj, Gladys Joysi M., Joe Raja Ruban M., D. AnnieCanisius
article en
4 citations

Abstract

In this study, we developed a non-enzymatic photoelectrochemical sensor using a BiOBr-CuO (BiCu) electrode, which was synthesized via solvothermal method. The sensor was designed for the simultaneous detection of glucose and tetracycline. Our study revealed that the BiCu electrode exhibited superior photocurrent generation compared to the individual BiOBr and CuO electrodes, as demonstrated by cyclic voltammetry and amperometric studies. The BiCu electrode's performance has increased due to the formation of a heterojunction between CuO and BiOBr, which modifies the UV–visible DRS spectrum and generates an internal electric field that reduces the recombination of the photogenerated carriers. This enhanced the capability of the sensor to detect both glucose and tetracycline. We successfully applied the proposed photoelectrochemical sensor to detect human blood glucose level. The sensitivity and detection limit for glucose and tetracycline are 0.1342 mAmM −1 cm −2 , 0.014 mM and 1.7234 mAmM −1 cm −2 , 2.0 μM respectively. Thus, the fabricated electrode demonstrated exceptional catalytic activity, high selectivity, good reproducibility, wide linear detection range, low limit of detection,long-term stability, ease of synthesis, good stability and notable selectivity for detecting both glucose and tetracycline This suggests that the BiCu electrode has significant potential as a reliable platform for the detection of glucose and tetracycline. • Results show the bifunctional ability of BiOBr-CuO as a sensor. • BiOBr-CuO electrode excels in simultaneous glucose and tetracycline detection. • Exhibits high sensitivity of 1.15133 mAmM −1 cm −2 and good selectivity (glucose). • Exhibits high sensitivity of 1.7234mAmM −1 cm −2 and good selectivity (tetracycline).

Sensors InternationalVol. 6
University of Madras (IN), Fahd bin Sultan University (SA), University of Tabuk (SA), Saveetha University (IN)
Openalex Percentile: Top 26%
Electrochemical sensors and biosensors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.