Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

Authors

Institutions

Publication Details

Published
2024-11-18
DOI
https://doi.org/10.2172/2477822
Primary Topic
CCD and CMOS Imaging Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

Toshihiko Imamura, S. Xie, C. Madrid, S. Nanda et al.
CCD and CMOS Imaging Sensors
article

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

Toshihiko Imamura, S. Xie, C. Madrid, S. Nanda, G. Giacomini, Cristián Peña, W. K. Brooks, S. Łoś, Sayuka Kita, O. K. Köseyan, Wei Chen, Z. Ye, C. E. Pérez Lara, H. Lee, César San Martín, Matías Barría, G. D’amen, A. Apresyan, Irene Dutta, R. Heller, K. Nakamura, Aram Hayrapetyan, A. Tricoli, J. Yoo
article en

Abstract

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

California Institute of Technology (US), Texas Tech University (US), Fermi National Accelerator Laboratory (US), A. Alikhanyan National Laboratory (AM), High Energy Accelerator Research Organization (JP), University of Tsukuba (JP), Valparaiso University (US), Kyungpook National University (KR), University of Chicago (US), Kyungpook National University Medical Center (KR), Federico Santa María Technical University (CL), Brookhaven College (US)
Affordable and clean energy
Openalex Percentile: Top 82%
CCD and CMOS Imaging Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.