Raman Spectroscopy Reveals Microparticles in Synovial Fluids of Patients With Suspected Implant‐Related Complications

ABSTRACT Prosthetic implant‐associated inflammation and failure can be caused by bacterial infections and mechanical wear of the prosthesis. Currently, there is no diagnostic modality that allows simultaneous identification of both causes of implant failure. Here, we present a proof‐of‐principle study to assess whether Raman spectroscopy can be applied to diagnose implant failure. Synovial fluids from 10 patients with a clinical suspicion of implant‐related complications were previously collected and cultured to determine the presence of bacteria. The presence of microparticles in these synovial fluids was assessed by Raman spectroscopy and verified by scanning electron microscopy combined with energy‐dispersive X‐ray spectroscopy (SEM‐EDX). For control, the possibility to detect in vitro ‐ cultured Staphylococcus aureus by Raman spectroscopy was investigated. Raman spectroscopy revealed that all 10 synovial fluid samples contained microparticles: eight contained microplastics (polyethylene, polypropylene, and polystyrene), and nine contained titanium dioxide nanoparticles (anatase and rutile) as verified by SEM‐EDX. There was no clear difference in the microparticle content of synovial fluids with or without bacteria. Raman signals relating to individual bacteria and clusters of bacteria were detectable in in vitro cultures of S. aureus , but it was not possible to demonstrate the presence of bacteria in synovial fluids by Raman spectroscopy. Raman spectroscopy is a potential tool for characterizing microparticles in synovial fluids from patients with implant‐related complications. This is of clinical relevance as these microparticles can cause joint inflammation. The identification of bacteria by Raman spectroscopy is feasible, but further research is needed before clinical implementation.

Authors

Institutions

Publication Details

Journal
Journal of Raman Spectroscopy
Published
2024-11-19
DOI
https://doi.org/10.1002/jrs.6753
Citations
1
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Raman Spectroscopy Reveals Microparticles in Synovial Fluids of Patients With Suspected Implant‐Related Complications

Marleen van Oosten, Tom Niessink, Cees Otto, Tim Jansen et al.
1 citations
Journal of Raman Spectroscopy
Orthopedic Infections and Treatments
0.57
article

Raman Spectroscopy Reveals Microparticles in Synovial Fluids of Patients With Suspected Implant‐Related Complications

Marleen van Oosten, Tom Niessink, Cees Otto, Tim Jansen, Jorrit W. A. Schoenmakers, Jan Maarten van Dijl, Sjouke Piersma, Marjan Wouthuyzen‐Bakker, Matthijs Janssen
article en
1 citations

Abstract

ABSTRACT Prosthetic implant‐associated inflammation and failure can be caused by bacterial infections and mechanical wear of the prosthesis. Currently, there is no diagnostic modality that allows simultaneous identification of both causes of implant failure. Here, we present a proof‐of‐principle study to assess whether Raman spectroscopy can be applied to diagnose implant failure. Synovial fluids from 10 patients with a clinical suspicion of implant‐related complications were previously collected and cultured to determine the presence of bacteria. The presence of microparticles in these synovial fluids was assessed by Raman spectroscopy and verified by scanning electron microscopy combined with energy‐dispersive X‐ray spectroscopy (SEM‐EDX). For control, the possibility to detect in vitro ‐ cultured Staphylococcus aureus by Raman spectroscopy was investigated. Raman spectroscopy revealed that all 10 synovial fluid samples contained microparticles: eight contained microplastics (polyethylene, polypropylene, and polystyrene), and nine contained titanium dioxide nanoparticles (anatase and rutile) as verified by SEM‐EDX. There was no clear difference in the microparticle content of synovial fluids with or without bacteria. Raman signals relating to individual bacteria and clusters of bacteria were detectable in in vitro cultures of S. aureus , but it was not possible to demonstrate the presence of bacteria in synovial fluids by Raman spectroscopy. Raman spectroscopy is a potential tool for characterizing microparticles in synovial fluids from patients with implant‐related complications. This is of clinical relevance as these microparticles can cause joint inflammation. The identification of bacteria by Raman spectroscopy is feasible, but further research is needed before clinical implementation.

Journal of Raman SpectroscopyVol. 56(2)
University Medical Center Groningen (NL), VieCuri Medisch Centrum (NL), University of Twente (NL)
Health~Holland
Openalex Percentile: Top 27%
Orthopedic Infections and Treatments
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.