Comparison of Intraocular Pressure Measurement by Air-Puff Tonometer and Goldmann Applanation Tonometer in Correlation to Corneal Pachymetry in Adolescence Age Group in Normal People

Abstract Purpose To assess the most accurate and practical technique for intraocular pressure (IOP) measurement in children and adolescents Type of the Study Cross-sectional observational Methods 90 eyes of 45 patients were included in this study. Central corneal thickness (CCT) was measured using specular microscopy. IOP was assessed by Goldman applanation tonometer (GAT), Non-contact tonometry (Air-puff), and Tono- Pen in both right and left eyes. Results The mean age of participants was 14.8 years. Mean CCT was 548.7 µm in the right eye and 549.2 µm in the left eye (P = 0.687). Mean IOP measured by GAT, Air-puff, and Tono-Pen was 11.7, 14.1, and 11.3 mmHg in the right eye, respectively, and 11.7, 14.2, and 11.5 mmHg in the left eye, respectively. Air-puff readings were significantly higher than GAT and Tono-Pen (P > 0.0001) in both the right and the left eyes. On the other hand, Tono-Pen showed no statistically significant difference from GAT measurements either in the right (P = 0.447) or the left eye (P = 1). The highest correlation with GAT was seen with the Air-puff. CCT was positively correlated with all used devices. Conclusion Tono-Pen provides the most accurate alternative for GAT. Although Air-puff offers a more accessible option for IOP measurement in adolescents, attention should be taken as it gives significantly higher measurements.

Authors

Institutions

Publication Details

Journal
QJM
Published
2024-10-01
DOI
https://doi.org/10.1093/qjmed/hcae175.621
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Intraocular Pressure Measurement by Air-Puff Tonometer and Goldmann Applanation Tonometer in Correlation to Corneal Pachymetry in Adolescence Age Group in Normal People

Doaa Ahmed, Maged Maher Salib Roshdy, Mona Kamal Abdellatif, Ahmed Abdelmonsef Abdelhamid Ebeid
QJM
Corneal surgery and disorders
article

Comparison of Intraocular Pressure Measurement by Air-Puff Tonometer and Goldmann Applanation Tonometer in Correlation to Corneal Pachymetry in Adolescence Age Group in Normal People

Doaa Ahmed, Maged Maher Salib Roshdy, Mona Kamal Abdellatif, Ahmed Abdelmonsef Abdelhamid Ebeid
article en

Abstract

Abstract Purpose To assess the most accurate and practical technique for intraocular pressure (IOP) measurement in children and adolescents Type of the Study Cross-sectional observational Methods 90 eyes of 45 patients were included in this study. Central corneal thickness (CCT) was measured using specular microscopy. IOP was assessed by Goldman applanation tonometer (GAT), Non-contact tonometry (Air-puff), and Tono- Pen in both right and left eyes. Results The mean age of participants was 14.8 years. Mean CCT was 548.7 µm in the right eye and 549.2 µm in the left eye (P = 0.687). Mean IOP measured by GAT, Air-puff, and Tono-Pen was 11.7, 14.1, and 11.3 mmHg in the right eye, respectively, and 11.7, 14.2, and 11.5 mmHg in the left eye, respectively. Air-puff readings were significantly higher than GAT and Tono-Pen (P > 0.0001) in both the right and the left eyes. On the other hand, Tono-Pen showed no statistically significant difference from GAT measurements either in the right (P = 0.447) or the left eye (P = 1). The highest correlation with GAT was seen with the Air-puff. CCT was positively correlated with all used devices. Conclusion Tono-Pen provides the most accurate alternative for GAT. Although Air-puff offers a more accessible option for IOP measurement in adolescents, attention should be taken as it gives significantly higher measurements.

QJMVol. 117(Supplement_2)
Ain Shams University (EG)
Openalex Percentile: Top 65%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Intraocular Pressure Measurement by Air-Puff Tonometer and Goldmann Applanation Tonometer in Correlation to Corneal Pachymetry in Adolescence Age Group in Normal People — Doaa Ahmed, Maged Maher Salib Roshdy, et al. · QJM (2024) | TGRS Research Map | TGRS