Green synthesized CaO decorated ternary CaO/g-C3N4/PVA nanocomposite modified glassy carbon electrode for enhanced electrochemical detection of caffeic acid

A highly selective, sensitive caffeic acid (CA) detection based on calcium oxide nanoparticles (CaO NPs) derived from extract of Moringa oleifera leaves decorated graphitic carbon nitride covalently grafted poly vinyl alcohol (CaO/g-C<sub>3</sub>N<sub>4</sub>/PVA) nanocomposite modified glassy carbon electrode (GCE) was studied. A facile sonochemical method was adapted to synthesis nanomaterials and characterized by HR-TEM (High resolution transmission electron microscopy), FT-IR (Fourier transform infrared spectroscopy), XRD (X-ray diffraction), FE-SEM (Field emission scanning electron microscopy), EDX (Energy dispersive X-ray analysis), Mapping and BET (Brunauer-Emmett-Teller) analysis, and electrochemical techniques. The nanocomposite modified GCE exhibited an excellent catalytic performance to the oxidation of CA under optimized conditions owing to better electron transfer efficiency, conductivity and high surface area of the electrode material. The present electrochemical sensor showed high selectivity towards the determination of 10 µM CA in the presence of 100-fold higher concentrations of interferents. The modified CA sensor exhibited a wide sensing linear range from 0.01 µM to 70 µM and the detection limit (LOD) was found to be 0.0024 µM (S/N = 3) in 0.1 M phosphate buffer saline (PBS) as a supporting electrolyte at pH 7.0. The fabricated CA sensor provides an excellent stability, reproducibility and selectivity for the determination of CA. The modified CA sensor was applied to real blood plasma samples and obtained good recovery (97.6-100.1%) results.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-20
DOI
https://doi.org/10.1038/s41598-024-80146-2
Citations
44
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
9.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Green synthesized CaO decorated ternary CaO/g-C3N4/PVA nanocomposite modified glassy carbon electrode for enhanced electrochemical detection of caffeic acid

Kar Ban Tan, C. Sudhakar, K.S. Anantharaju, H. C. Ananda Murthy et al.
44 citations
Scientific Reports
Electrochemical sensors and biosensors
9.18
article

Green synthesized CaO decorated ternary CaO/g-C3N4/PVA nanocomposite modified glassy carbon electrode for enhanced electrochemical detection of caffeic acid

Kar Ban Tan, C. Sudhakar, K.S. Anantharaju, H. C. Ananda Murthy, Baluchamy Tamilselvi, P. Karuppasamy, S. Meena, Annamalai Karthika
article en
44 citations

Abstract

A highly selective, sensitive caffeic acid (CA) detection based on calcium oxide nanoparticles (CaO NPs) derived from extract of Moringa oleifera leaves decorated graphitic carbon nitride covalently grafted poly vinyl alcohol (CaO/g-C<sub>3</sub>N<sub>4</sub>/PVA) nanocomposite modified glassy carbon electrode (GCE) was studied. A facile sonochemical method was adapted to synthesis nanomaterials and characterized by HR-TEM (High resolution transmission electron microscopy), FT-IR (Fourier transform infrared spectroscopy), XRD (X-ray diffraction), FE-SEM (Field emission scanning electron microscopy), EDX (Energy dispersive X-ray analysis), Mapping and BET (Brunauer-Emmett-Teller) analysis, and electrochemical techniques. The nanocomposite modified GCE exhibited an excellent catalytic performance to the oxidation of CA under optimized conditions owing to better electron transfer efficiency, conductivity and high surface area of the electrode material. The present electrochemical sensor showed high selectivity towards the determination of 10 µM CA in the presence of 100-fold higher concentrations of interferents. The modified CA sensor exhibited a wide sensing linear range from 0.01 µM to 70 µM and the detection limit (LOD) was found to be 0.0024 µM (S/N = 3) in 0.1 M phosphate buffer saline (PBS) as a supporting electrolyte at pH 7.0. The fabricated CA sensor provides an excellent stability, reproducibility and selectivity for the determination of CA. The modified CA sensor was applied to real blood plasma samples and obtained good recovery (97.6-100.1%) results.

Scientific ReportsVol. 14(1)
Papua New Guinea University of Technology (PG), Universiti Putra Malaysia (MY), CMR University (IN), Saveetha University (IN), Dr. Hari Singh Gour University (IN)
Openalex Percentile: Top 1%
Electrochemical sensors and biosensors
9.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.