Wear, Material Transfer, and Electrocautery Damage Are Ubiquitous on <scp>CoCrMo</scp> Femoral Knee Retrievals

Despite high total knee arthroplasty (TKA) survivorship after 10 years (92%-99%), a gap persists where patient satisfaction lags clinical success. Additionally, while cobalt chrome molybdenum (CoCrMo) use decreases in primary total hip arthroplasty, the alloy continues to be widely used in TKA femoral components. In vivo, CoCrMo degradation may be associated with adverse local tissue reactions (ALTR) and compared with the hip, the damage mechanisms that may release metal in the knee and the potential biological effects remain poorly understood. In this study, we characterized the damage on 50 retrieved CoCrMo femoral knee implants paired with 19 titanium alloy and 31 CoCrMo tibial baseplates. We asked (1) what damage modes can release CoCrMo debris in vivo from femoral components and (2) how frequently does the damage occur? First, we developed a semiquantitative scoring system for abrasive wear. Then, we characterized damage modes on CoCrMo femoral implants using digital optical microscopy (DOM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). We found that wear, electrocautery damage, and Ti-6Al-4V material transfer were ubiquitous. Of the 50 CoCrMo femoral implants we investigated, we documented wear on 100% (n = 50/50), electrocautery damage on 98% (n = 49/50), and Ti-6Al-4V material transfer to the posterior condyles on 95% (n = 18/19). Our results suggest that these damage modes may be more prevalent than previously thought and may act as metal release mechanisms in vivo.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2024-11-20
DOI
https://doi.org/10.1002/jbm.b.35504
Citations
7
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
4.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wear, Material Transfer, and Electrocautery Damage Are Ubiquitous on CoCrMo Femoral Knee Retrievals

Peter W. Kurtz, Charley M. Goodwin, Michael A. Kurtz, Jeremy L. Gilbert et al.
7 citations
Journal of Biomedical Materials Research Part B Applied Biomaterials
Orthopaedic implants and arthroplasty
4.01
article

Wear, Material Transfer, and Electrocautery Damage Are Ubiquitous on CoCrMo Femoral Knee Retrievals

Peter W. Kurtz, Charley M. Goodwin, Michael A. Kurtz, Jeremy L. Gilbert, William M. Mihalko, Nicolas Santiago Piuzzi, Steven M. Kurtz, Daniel W. MacDonald, Lilliana M. Taylor, S Aslani
article en
7 citations

Abstract

Despite high total knee arthroplasty (TKA) survivorship after 10 years (92%-99%), a gap persists where patient satisfaction lags clinical success. Additionally, while cobalt chrome molybdenum (CoCrMo) use decreases in primary total hip arthroplasty, the alloy continues to be widely used in TKA femoral components. In vivo, CoCrMo degradation may be associated with adverse local tissue reactions (ALTR) and compared with the hip, the damage mechanisms that may release metal in the knee and the potential biological effects remain poorly understood. In this study, we characterized the damage on 50 retrieved CoCrMo femoral knee implants paired with 19 titanium alloy and 31 CoCrMo tibial baseplates. We asked (1) what damage modes can release CoCrMo debris in vivo from femoral components and (2) how frequently does the damage occur? First, we developed a semiquantitative scoring system for abrasive wear. Then, we characterized damage modes on CoCrMo femoral implants using digital optical microscopy (DOM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). We found that wear, electrocautery damage, and Ti-6Al-4V material transfer were ubiquitous. Of the 50 CoCrMo femoral implants we investigated, we documented wear on 100% (n = 50/50), electrocautery damage on 98% (n = 49/50), and Ti-6Al-4V material transfer to the posterior condyles on 95% (n = 18/19). Our results suggest that these damage modes may be more prevalent than previously thought and may act as metal release mechanisms in vivo.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 112(12)
Cleveland Clinic (US), Medical University of South Carolina (US), University of Tennessee Health Science Center (US), Campbell Clinic (US), Drexel University (US), Clemson University (US)
Life below water
Openalex Percentile: Top 6%
Orthopaedic implants and arthroplasty
4.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.