Impact of Titanium Cranial Implants on the Electric Field and SAR Distribution Induced by Mobile Phones Within the User’s Head

The purpose of this study was to determine the impact of a titanium cranial implant on the electric field distribution and the amount of energy absorbed from a cell phone within the human head. Three-dimensional lifelike models of the head of the mobile phone user, a titanium cranial implant, and a smartphone model was built. The head model consisted of sixteen homogeneous, isotropic domains, with permittivity and conductivity parameters taken from the literature. Numerical calculations were performed at the mobile communication frequency of 2600 MHz for a head model with and without a titanium cranial implant, in order to determine a field perturbation introduced by the implant. Our results show that in the presence of a titanium cranial implant, the electric field amplitude and SAR (Specific Absorption Rate) are increased within the layers close to the outer surface of the model (skin, fat tissue, and muscle). On the other hand, a cranial implant leads to a lower penetration depth, decreasing the electric field amplitude and SAR inside the skull, cerebrospinal fluid, and brain.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-11-20
DOI
https://doi.org/10.3390/electronics13224551
Citations
2
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Titanium Cranial Implants on the Electric Field and SAR Distribution Induced by Mobile Phones Within the User’s Head

Dragana Živaljević, Nenad Cvetković, Dragan Krasić, Bojana Petković et al.
2 citations
Electronics
Wireless Body Area Networks
0.37
article

Impact of Titanium Cranial Implants on the Electric Field and SAR Distribution Induced by Mobile Phones Within the User’s Head

Dragana Živaljević, Nenad Cvetković, Dragan Krasić, Bojana Petković, Dejan Jovanović
article en
2 citations

Abstract

The purpose of this study was to determine the impact of a titanium cranial implant on the electric field distribution and the amount of energy absorbed from a cell phone within the human head. Three-dimensional lifelike models of the head of the mobile phone user, a titanium cranial implant, and a smartphone model was built. The head model consisted of sixteen homogeneous, isotropic domains, with permittivity and conductivity parameters taken from the literature. Numerical calculations were performed at the mobile communication frequency of 2600 MHz for a head model with and without a titanium cranial implant, in order to determine a field perturbation introduced by the implant. Our results show that in the presence of a titanium cranial implant, the electric field amplitude and SAR (Specific Absorption Rate) are increased within the layers close to the outer surface of the model (skin, fat tissue, and muscle). On the other hand, a cranial implant leads to a lower penetration depth, decreasing the electric field amplitude and SAR inside the skull, cerebrospinal fluid, and brain.

ElectronicsVol. 13(22)
Technische Universität Ilmenau (DE), University of Nis (RS)
Affordable and clean energy
Openalex Percentile: Top 42%
Wireless Body Area Networks
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.