Phasor estimation using micro-phasor measurement unit (μPMU) in distribution network for situational awareness

Abstract Phasor estimation plays a critical role in island detection, fault detection, voltage stability monitoring, and state estimation within power systems. This paper proposes a phasor estimation method using micro-Phasor Measurement Units (µPMUs) in a Smart Distribution Network. A µPMU model is developed utilizing a recursive Discrete Fourier Transform (DFT) algorithm combined with high-precision filters to enhance accuracy. The optimal placement of µPMUs in the distribution network is determined using a Mixed-Integer Linear Programming (MILP) approach for the IEEE 33 bus test system. The model is tested on the IEEE 33 bus system with Electric Vehicle Charging Stations (EVCS) and Distributed Generators (DGs) under both nominal and off-nominal frequencies. The results comply with the IEEE C37.118.1 standard, achieving phasor magnitude errors as low as + 0.01% and frequency accuracy of 1 mHz with minimal ripple. This study demonstrates the robustness and precision of the µPMU model, highlighting its potential for enhancing real-time monitoring and control in smart grid applications.

Authors

Institutions

Publication Details

Journal
Journal of Electrical Systems and Information Technology
Published
2024-11-20
DOI
https://doi.org/10.1186/s43067-024-00179-5
Citations
5
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phasor estimation using micro-phasor measurement unit (μPMU) in distribution network for situational awareness

Swapna Mansani, B Deepa, Santoshkumar Hampannavar
5 citations
Journal of Electrical Systems and Information Technology
Power System Optimization and Stability
1.04
article

Phasor estimation using micro-phasor measurement unit (μPMU) in distribution network for situational awareness

Swapna Mansani, B Deepa, Santoshkumar Hampannavar
article en
5 citations

Abstract

Abstract Phasor estimation plays a critical role in island detection, fault detection, voltage stability monitoring, and state estimation within power systems. This paper proposes a phasor estimation method using micro-Phasor Measurement Units (µPMUs) in a Smart Distribution Network. A µPMU model is developed utilizing a recursive Discrete Fourier Transform (DFT) algorithm combined with high-precision filters to enhance accuracy. The optimal placement of µPMUs in the distribution network is determined using a Mixed-Integer Linear Programming (MILP) approach for the IEEE 33 bus test system. The model is tested on the IEEE 33 bus system with Electric Vehicle Charging Stations (EVCS) and Distributed Generators (DGs) under both nominal and off-nominal frequencies. The results comply with the IEEE C37.118.1 standard, achieving phasor magnitude errors as low as + 0.01% and frequency accuracy of 1 mHz with minimal ripple. This study demonstrates the robustness and precision of the µPMU model, highlighting its potential for enhancing real-time monitoring and control in smart grid applications.

Journal of Electrical Systems and Information TechnologyVol. 11(1)
National Institute Of Technology Silchar (IN), University of Johannesburg (ZA), REVA University (IN)
Openalex Percentile: Top 22%
Power System Optimization and Stability
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.