A novel method for computing the full-energy peak efficiency of coaxial high-purity germanium detectors for cylindrical sources

In this work a novel method for computing the full-energy peak efficiency of coaxial HPGe detectors for cylindrical sources emitting photons in the range of 60–2000 keV is described. It has a solid theoretical basis using an integral expression for computing the full-energy peak efficiency via computed values of the detector response and the attenuation factor of point sources. The method was implemented as a Matlab code written for computing the full-energy peak efficiency of a Canberra detector. The code was extensively verified by intercomparison with GESPECOR and LabSOCS codes and the results are fit purpose e.g. in the measurement of environmental samples.

Authors

Publication Details

Journal
Romanian Reports in Physics
Published
2024-11-20
DOI
https://doi.org/10.59277/romrepphys.2024.76.805
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for computing the full-energy peak efficiency of coaxial high-purity germanium detectors for cylindrical sources

G. Ilie, Daniela Gurau, L. Done, D. Stânga et al.
Romanian Reports in Physics
Radioactivity and Radon Measurements
article

A novel method for computing the full-energy peak efficiency of coaxial high-purity germanium detectors for cylindrical sources

G. Ilie, Daniela Gurau, L. Done, D. Stânga, O. Sima
article en

Abstract

In this work a novel method for computing the full-energy peak efficiency of coaxial HPGe detectors for cylindrical sources emitting photons in the range of 60–2000 keV is described. It has a solid theoretical basis using an integral expression for computing the full-energy peak efficiency via computed values of the detector response and the attenuation factor of point sources. The method was implemented as a Matlab code written for computing the full-energy peak efficiency of a Canberra detector. The code was extensively verified by intercomparison with GESPECOR and LabSOCS codes and the results are fit purpose e.g. in the measurement of environmental samples.

Romanian Reports in PhysicsVol. 76(4)
Affordable and clean energy
Openalex Percentile: Top 68%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.