Initial Experience With Senhance-Assisted Laparoscopic Partial Cystectomy Using the Double Bipolar Method With 3 mm Bipolar Instruments

The Senhance robotic system (Asensus Surgical, Durham, NC, USA) is an innovative platform for minimally invasive surgery. It enables surgeons to perform precise and cost-effective procedures using reusable instruments and has advanced features such as haptic feedback and eye-tracking camera control. Herein, we present the first application of the "double bipolar method" (DBM) in a Senhance-assisted laparoscopic partial cystectomy utilizing 3 mm Maryland bipolar instruments. The DBM technique allows for the simultaneous use of bipolar instruments in both hands, thereby providing exceptional control in tissue dissection and coagulation, which are critical for delicate urologic procedures such as partial cystectomy. We present a case of a 62-year-old female patient who had a 2 cm tumor located at the bladder's dome. Following comprehensive preoperative imaging and cystoscopic evaluation, the tumor was deemed suitable for resection using the Senhance system. The DBM technique enabled the precise and bloodless resection of the bladder wall. Intraoperative evaluation confirmed the complete removal of the tumor and the successful closure of the bladder defect using a barbed suture. The patient had an uncomplicated recovery and was discharged on the eighth postoperative day. The combination of Senhance's advanced features and the DBM technique with 3 mm instruments offers a significant advantage in urologic surgery, providing enhanced precision, cost-efficiency, and improved cosmetic outcomes. The DBM technique in conjunction with the Senhance system represents a promising approach for bladder-sparing surgeries, with the potential for widespread adoption in clinical practice.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-11-20
DOI
https://doi.org/10.7759/cureus.74074
Citations
1
Primary Topic
Bladder and Urothelial Cancer Treatments
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial Experience With Senhance-Assisted Laparoscopic Partial Cystectomy Using the Double Bipolar Method With 3 mm Bipolar Instruments

Go Kaneko, Suguru Shirotake, Isamu Koyama, Masafumi Oyama et al.
1 citations
Cureus
Bladder and Urothelial Cancer Treatments
0.57
article

Initial Experience With Senhance-Assisted Laparoscopic Partial Cystectomy Using the Double Bipolar Method With 3 mm Bipolar Instruments

Go Kaneko, Suguru Shirotake, Isamu Koyama, Masafumi Oyama, Junya Kawabata, Suguru Matsushita, Taku Homma
article en
1 citations

Abstract

The Senhance robotic system (Asensus Surgical, Durham, NC, USA) is an innovative platform for minimally invasive surgery. It enables surgeons to perform precise and cost-effective procedures using reusable instruments and has advanced features such as haptic feedback and eye-tracking camera control. Herein, we present the first application of the "double bipolar method" (DBM) in a Senhance-assisted laparoscopic partial cystectomy utilizing 3 mm Maryland bipolar instruments. The DBM technique allows for the simultaneous use of bipolar instruments in both hands, thereby providing exceptional control in tissue dissection and coagulation, which are critical for delicate urologic procedures such as partial cystectomy. We present a case of a 62-year-old female patient who had a 2 cm tumor located at the bladder's dome. Following comprehensive preoperative imaging and cystoscopic evaluation, the tumor was deemed suitable for resection using the Senhance system. The DBM technique enabled the precise and bloodless resection of the bladder wall. Intraoperative evaluation confirmed the complete removal of the tumor and the successful closure of the bladder defect using a barbed suture. The patient had an uncomplicated recovery and was discharged on the eighth postoperative day. The combination of Senhance's advanced features and the DBM technique with 3 mm instruments offers a significant advantage in urologic surgery, providing enhanced precision, cost-efficiency, and improved cosmetic outcomes. The DBM technique in conjunction with the Senhance system represents a promising approach for bladder-sparing surgeries, with the potential for widespread adoption in clinical practice.

CureusVol. 16(11)
Saitama International Medical Center (JP), Saitama Medical University (JP)
Saitama Medical University
Openalex Percentile: Top 27%
Bladder and Urothelial Cancer Treatments
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.