Mechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results

<b>Background:</b> This study aims to investigate the impact of test conditions on the results of the compression testing of microneedle arrays (MNAs). <b>Methods:</b> Uniaxial compression tests were conducted on polyglycolic acid-fabricated biodegradable MNAs. Load-displacement curves were obtained for varying conditions, including the number of microneedles (MNs) compressed simultaneously, compression speeds, and compression angles. Subsequently, the buckling load and stiffness were calculated, and the MN deformation during compression was observed. <b>Results:</b> The buckling load and stiffness per MN decreased significantly with a simultaneous increase in compressed MNs. The mean buckling load and stiffness of 52 MNs in single-needle compression tests were 0.211 ± 0.008 N and 13.9 ± 1.3 N/mm, respectively, with no variation among the three MNAs. However, a significant difference in buckling load and stiffness was observed among the MNs within the MNAs. Additionally, buckling loads and stiffnesses were significantly lower in certain MNs at the same location in different MNAs. Buckling load and stiffness decreased significantly during inclined compression compared to during vertical compression. While the tests evaluate the mechanical properties of MNAs, test results may vary depending on test conditions. <b>Conclusions:</b> Compression testing of the individual MNs comprising an MNA helps evaluate the mechanical properties of MNs and ensure the quality of MNAs.

Authors

Institutions

Publication Details

Journal
Pharmaceutics
Published
2024-11-20
DOI
https://doi.org/10.3390/pharmaceutics16111480
Citations
11
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
2.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results

Y. Nomura, Hideyuki Sakoda, Eiichi Yamamoto, Yusuke Tsuboko et al.
11 citations
Pharmaceutics
Advancements in Transdermal Drug Delivery
2.29
article

Mechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results

Y. Nomura, Hideyuki Sakoda, Eiichi Yamamoto, Yusuke Tsuboko, Yoshihiro Okamoto
article en
11 citations

Abstract

<b>Background:</b> This study aims to investigate the impact of test conditions on the results of the compression testing of microneedle arrays (MNAs). <b>Methods:</b> Uniaxial compression tests were conducted on polyglycolic acid-fabricated biodegradable MNAs. Load-displacement curves were obtained for varying conditions, including the number of microneedles (MNs) compressed simultaneously, compression speeds, and compression angles. Subsequently, the buckling load and stiffness were calculated, and the MN deformation during compression was observed. <b>Results:</b> The buckling load and stiffness per MN decreased significantly with a simultaneous increase in compressed MNs. The mean buckling load and stiffness of 52 MNs in single-needle compression tests were 0.211 ± 0.008 N and 13.9 ± 1.3 N/mm, respectively, with no variation among the three MNAs. However, a significant difference in buckling load and stiffness was observed among the MNs within the MNAs. Additionally, buckling loads and stiffnesses were significantly lower in certain MNs at the same location in different MNAs. Buckling load and stiffness decreased significantly during inclined compression compared to during vertical compression. While the tests evaluate the mechanical properties of MNAs, test results may vary depending on test conditions. <b>Conclusions:</b> Compression testing of the individual MNs comprising an MNA helps evaluate the mechanical properties of MNs and ensure the quality of MNAs.

PharmaceuticsVol. 16(11)
National Institute of Health Sciences (JP)
Japan Agency for Medical Research and Development, Ministry of Health, Labour and Welfare
Clean water and sanitation
Openalex Percentile: Top 12%
Advancements in Transdermal Drug Delivery
2.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Mechanical Characterization of Individual Needles in Microneedle Arrays: Factors Affecting Compression Test Results — Y. Nomura, Hideyuki Sakoda, et al. · Pharmaceutics (2024) | TGRS Research Map | TGRS