In Situ Monitoring of Anodic Acidification Process Using 3D μ-XCT Method

Debonding of the primary anode caused by anodic acidification is one of the major failure modes of the impressed current cathodic protection (ICCP) system in reinforced concrete structures. This study used 3D micro X-ray computed tomography (μ-XCT) to monitor the in situ evolution of the anodic acidification-affected zone. Samples were scanned after 0 to 40 days of the accelerated anodic acidification test. The anodic acidification-affected zone was identified in μ-XCT images using the gray level segmentation method. The total volume of this zone was measured using the 3D reconstruction method. It was found that detailed 3D information can be extracted using the 3D reconstruction method. The spatial heterogeneity was analyzed using this reconstructed volume information. The Faraday efficiency was calculated and found to increase after 20 days of operation. It was also found that the affected zone was proportional to the input electrical energy. The proposed model is useful for estimating the durability of an ICCP system.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-11-20
DOI
https://doi.org/10.3390/ma17225662
Citations
2
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Situ Monitoring of Anodic Acidification Process Using 3D μ-XCT Method

Chaoqun Zeng, Miaochang Zhu, Shanshan Qin, Zhijun Deng
2 citations
Materials
Concrete Corrosion and Durability
0.52
article

In Situ Monitoring of Anodic Acidification Process Using 3D μ-XCT Method

Chaoqun Zeng, Miaochang Zhu, Shanshan Qin, Zhijun Deng
article en
2 citations

Abstract

Debonding of the primary anode caused by anodic acidification is one of the major failure modes of the impressed current cathodic protection (ICCP) system in reinforced concrete structures. This study used 3D micro X-ray computed tomography (μ-XCT) to monitor the in situ evolution of the anodic acidification-affected zone. Samples were scanned after 0 to 40 days of the accelerated anodic acidification test. The anodic acidification-affected zone was identified in μ-XCT images using the gray level segmentation method. The total volume of this zone was measured using the 3D reconstruction method. It was found that detailed 3D information can be extracted using the 3D reconstruction method. The spatial heterogeneity was analyzed using this reconstructed volume information. The Faraday efficiency was calculated and found to increase after 20 days of operation. It was also found that the affected zone was proportional to the input electrical energy. The proposed model is useful for estimating the durability of an ICCP system.

MaterialsVol. 17(22)
Guangdong University of Technology (CN), Shenzhen Polytechnic University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province, Basic and Applied Basic Research Foundation of Guangdong Province
Openalex Percentile: Top 35%
Concrete Corrosion and Durability
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In Situ Monitoring of Anodic Acidification Process Using 3D μ-XCT Method — Chaoqun Zeng, Miaochang Zhu, et al. · Materials (2024) | TGRS Research Map | TGRS