Effects of inlet boundary conditions on blood flow and thrombosis modelling in patients with chronic thromboembolic pulmonary hypertension

To investigate the impact of patient-specific boundary conditions (BC) on blood flow and thrombosis modelling for patients with chronic thromboembolic pulmonary hypertension (CTEPH), three types of BCs were utilized to construct CTEPH models based on computed tomography pulmonary angiography images. First BC type is the patient-specific velocity profiles at the main pulmonary artery using phase contrast MRI (PC-MRI). The other two simplified types are the pulsatile BC and steady BC, which are obtained by spatially and temporally averaging the PC-MRI BC. Hemodynamic features including helical density, time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI), and thrombosis were compared for the three types BCs. The results indicated that, compared to the MRI BC, steady BC overestimated helical density and TAWSS in the pulmonary arteries by approximately 63.1% and 60%, respectively. The impact of simplified pulsatile BC on TAWSS and OSI in most regions of the pulmonary arteries was negligible with differences within 5%. Regarding thrombosis, the area predicted under pulsatile BC was approximately 80% smaller than that under PC-MRI BC. In conclusion, compared to PC-MRI BC, steady inlet BC tend to overestimate hemodynamic parameters, while pulsatile inlet BC yield similar wall shear stress based on parameters in most regions of the pulmonary artery. Patient-specific PC-MRI inlet BC should be used for accurate predictions of helical flow pattern and thrombus formation.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2024-11-20
DOI
https://doi.org/10.1080/10255842.2024.2429789
Primary Topic
Pulmonary Hypertension Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of inlet boundary conditions on blood flow and thrombosis modelling in patients with chronic thromboembolic pulmonary hypertension

Yueming Hao, Zhenguo Zhai, Hui Wu, Linfeng Xi et al.
Computer Methods in Biomechanics & Biomedical Engineering
Pulmonary Hypertension Research and Treatments
article

Effects of inlet boundary conditions on blood flow and thrombosis modelling in patients with chronic thromboembolic pulmonary hypertension

Yueming Hao, Zhenguo Zhai, Hui Wu, Linfeng Xi, Qiang Huang, Min Liu, Tianxiang Ma, Xiaoyan Deng, Xiao Liu
article en

Abstract

To investigate the impact of patient-specific boundary conditions (BC) on blood flow and thrombosis modelling for patients with chronic thromboembolic pulmonary hypertension (CTEPH), three types of BCs were utilized to construct CTEPH models based on computed tomography pulmonary angiography images. First BC type is the patient-specific velocity profiles at the main pulmonary artery using phase contrast MRI (PC-MRI). The other two simplified types are the pulsatile BC and steady BC, which are obtained by spatially and temporally averaging the PC-MRI BC. Hemodynamic features including helical density, time-averaged wall shear stress (TAWSS) and oscillatory shear index (OSI), and thrombosis were compared for the three types BCs. The results indicated that, compared to the MRI BC, steady BC overestimated helical density and TAWSS in the pulmonary arteries by approximately 63.1% and 60%, respectively. The impact of simplified pulsatile BC on TAWSS and OSI in most regions of the pulmonary arteries was negligible with differences within 5%. Regarding thrombosis, the area predicted under pulsatile BC was approximately 80% smaller than that under PC-MRI BC. In conclusion, compared to PC-MRI BC, steady inlet BC tend to overestimate hemodynamic parameters, while pulsatile inlet BC yield similar wall shear stress based on parameters in most regions of the pulmonary artery. Patient-specific PC-MRI inlet BC should be used for accurate predictions of helical flow pattern and thrombus formation.

Computer Methods in Biomechanics & Biomedical Engineering
Capital Medical University (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), China-Japan Friendship Hospital (CN), Beihang University (CN)
National Natural Science Foundation of China, Higher Education Discipline Innovation Project
Openalex Percentile: Top 61%
Pulmonary Hypertension Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.