Evaluation of a Commercially Available Radiochromic Film for Use as a Complementary Dosimeter for Rapid In-field Low Photon Equivalent Radiation Dose (≤50 mSv) Monitoring

This work investigates the low photon radiation dose (≤50 mSv) response of commercially available radiochromic films as a potential field dosimeter that could be used by the Canadian Armed Forces to complement their existing personal radiation dosimeters. The films were exposed to various photon energies from x-ray devices and radioisotopes (cesium-137, cobalt-60, and americium-241), and their radiation signal was read using three methods: net optical density, UV/visible spectroscopy, and Fourier transform infrared spectroscopy. A complimentary film dosimeter for field usage should, for military use, display a visual color change and detect doses ≤50 mSv. Given the film's radiochromic properties, it was determined that the net optical density method was the most optimal read-out method, which ascertained a minimum detection dose limit of 4.5 mSv under exposure to a clinical orthovoltage operated at 100 kVp. The film presented an overall linear relationship between net optical density and radiation dose; however, they also portrayed a photon energy-dependent response between 0-100 mSv. Overall, the radiochromic films presented a real-time visual dose signal that could be interpreted rapidly in a mobile laboratory and possessed the ability to detect photon doses ≤50 mSv below the vendor's recommended limits, making it a suitable option as a complementary, disposable, military dosimetric tool. Future work includes the investigation of the film's response under multi- and unknown source environments and environmental-dependent factors such as UV/sunlight exposure and extreme temperatures.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2024-11-20
DOI
https://doi.org/10.1097/hp.0000000000001903
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of a Commercially Available Radiochromic Film for Use as a Complementary Dosimeter for Rapid In-field Low Photon Equivalent Radiation Dose (≤50 mSv) Monitoring

Ana Pejović‐Milić, Helen Moise, Nicky Nivi
Health Physics
Advanced Radiotherapy Techniques
article

Evaluation of a Commercially Available Radiochromic Film for Use as a Complementary Dosimeter for Rapid In-field Low Photon Equivalent Radiation Dose (≤50 mSv) Monitoring

Ana Pejović‐Milić, Helen Moise, Nicky Nivi
article en

Abstract

This work investigates the low photon radiation dose (≤50 mSv) response of commercially available radiochromic films as a potential field dosimeter that could be used by the Canadian Armed Forces to complement their existing personal radiation dosimeters. The films were exposed to various photon energies from x-ray devices and radioisotopes (cesium-137, cobalt-60, and americium-241), and their radiation signal was read using three methods: net optical density, UV/visible spectroscopy, and Fourier transform infrared spectroscopy. A complimentary film dosimeter for field usage should, for military use, display a visual color change and detect doses ≤50 mSv. Given the film's radiochromic properties, it was determined that the net optical density method was the most optimal read-out method, which ascertained a minimum detection dose limit of 4.5 mSv under exposure to a clinical orthovoltage operated at 100 kVp. The film presented an overall linear relationship between net optical density and radiation dose; however, they also portrayed a photon energy-dependent response between 0-100 mSv. Overall, the radiochromic films presented a real-time visual dose signal that could be interpreted rapidly in a mobile laboratory and possessed the ability to detect photon doses ≤50 mSv below the vendor's recommended limits, making it a suitable option as a complementary, disposable, military dosimetric tool. Future work includes the investigation of the film's response under multi- and unknown source environments and environmental-dependent factors such as UV/sunlight exposure and extreme temperatures.

Health PhysicsVol. 128(5)
Defence Research and Development Canada (CA), Toronto Metropolitan University (CA)
Openalex Percentile: Top 71%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.