Ventilation characteristics in a hospital where a COVID-19 outbreak occurred in the winter of 2020

To clear the influences of ventilation performance on COVID-19 outbreaks in hospitals, the ventilation characteristics were investigated in a ward of an over-30-year-old hospital where a large outbreak occurred in the winter of 2020. At the early stage of the outbreak, nasal high-flow (NHF) was used in a treatment room for a week, and many patients stayed in multi-bed rooms during the outbreak. The viruses could expand not only with the infected staff or patients but also with the virus-contained air. To make an emergent ventilation measure plan, which the hospital requested, the actual performance of the air-conditioning and ventilation system and the ventilation characteristics were investigated using airflow volume meters, smoke testers, and a tracer gas CO 2 . The results of the measurements and the analysis showed the following. The ventilation rates had decreased to 30 % of the design value in the ward. The ventilation rate was decreased to 10 % in the treatment room where NHF was used, and the ventilation rates were decreased to 4–31 % in the rooms with six beds. The room doors were usually opened, and the opening had the effect of increasing the ventilation rate of the room. However, the virus-contained air could expand to the corridor and the other spaces. The air supply is stopped to keep room temperature at night, and the ventilation is thought to be very poor, especially if the doors are closed. Inadequate ventilation in the old buildings may have affected the hospital outbreak cases. It is essential to check the ventilation characteristics regularly, especially in old buildings. The result contributed to the administrative notice “The Emergent Ventilation Measures to Control COVID-19 in Hospitals” in April 2021 in Japan.

Authors

Institutions

Publication Details

Journal
Indoor Environments
Published
2024-11-20
DOI
https://doi.org/10.1016/j.indenv.2024.100065
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventilation characteristics in a hospital where a COVID-19 outbreak occurred in the winter of 2020

Motoya Hayashi, Koki Kikuta, Sayaka Murata
Indoor Environments
Infection Control and Ventilation
article

Ventilation characteristics in a hospital where a COVID-19 outbreak occurred in the winter of 2020

Motoya Hayashi, Koki Kikuta, Sayaka Murata
article en

Abstract

To clear the influences of ventilation performance on COVID-19 outbreaks in hospitals, the ventilation characteristics were investigated in a ward of an over-30-year-old hospital where a large outbreak occurred in the winter of 2020. At the early stage of the outbreak, nasal high-flow (NHF) was used in a treatment room for a week, and many patients stayed in multi-bed rooms during the outbreak. The viruses could expand not only with the infected staff or patients but also with the virus-contained air. To make an emergent ventilation measure plan, which the hospital requested, the actual performance of the air-conditioning and ventilation system and the ventilation characteristics were investigated using airflow volume meters, smoke testers, and a tracer gas CO 2 . The results of the measurements and the analysis showed the following. The ventilation rates had decreased to 30 % of the design value in the ward. The ventilation rate was decreased to 10 % in the treatment room where NHF was used, and the ventilation rates were decreased to 4–31 % in the rooms with six beds. The room doors were usually opened, and the opening had the effect of increasing the ventilation rate of the room. However, the virus-contained air could expand to the corridor and the other spaces. The air supply is stopped to keep room temperature at night, and the ventilation is thought to be very poor, especially if the doors are closed. Inadequate ventilation in the old buildings may have affected the hospital outbreak cases. It is essential to check the ventilation characteristics regularly, especially in old buildings. The result contributed to the administrative notice “The Emergent Ventilation Measures to Control COVID-19 in Hospitals” in April 2021 in Japan.

Indoor EnvironmentsVol. 2(1)
Hokkaido University (JP), Hokkaido Research Organization (JP)
Openalex Percentile: Top 61%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ventilation characteristics in a hospital where a COVID-19 outbreak occurred in the winter of 2020 — Motoya Hayashi, Koki Kikuta, et al. · Indoor Environments (2024) | TGRS Research Map | TGRS