A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant

Bone-anchored percutaneous implants, commonly referred to as osseointegrated implants, are gaining popularity as an alternative to sockets for attaching a prosthetic limb to an amputated femur. While these implants have several advantages, femoral fractures are relatively common in these patients, occurring in 6.3% of femurs within 4 years. This study aimed to develop a novel method to quantify femoral strength under all possible external loads acting on the distal implant. Finite element analysis was used to explore combinations of forces and moments that, when applied on the bone-anchored implant, were just sufficient to fracture the femur. The 6-dimensional envelope generated in the current study provided a quantitative description of the strength of the femur-implant construct. All the femoral fractures were predicted in the trochanteric region, corresponding to where most in vivo fractures have been reported. The 6-dimensional envelopes developed in the current study may be useful in the design of fail-safe devices that could reduce femoral fractures in patients with bone-anchored percutaneous femoral implants. The framework presented may also be used for determining patient suitability for bone-anchored percutaneous implants, and for evaluating the functional performance of implant designs.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-11-20
DOI
https://doi.org/10.1038/s41598-024-78421-3
Citations
1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant

Dale L. Robinson, Peter Vee Sin Lee, David C. Ackland, Hans A. Gray et al.
1 citations
Scientific Reports
Orthopaedic implants and arthroplasty
0.57
article

A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant

Dale L. Robinson, Peter Vee Sin Lee, David C. Ackland, Hans A. Gray, Ryan Tiew
article en
1 citations

Abstract

Bone-anchored percutaneous implants, commonly referred to as osseointegrated implants, are gaining popularity as an alternative to sockets for attaching a prosthetic limb to an amputated femur. While these implants have several advantages, femoral fractures are relatively common in these patients, occurring in 6.3% of femurs within 4 years. This study aimed to develop a novel method to quantify femoral strength under all possible external loads acting on the distal implant. Finite element analysis was used to explore combinations of forces and moments that, when applied on the bone-anchored implant, were just sufficient to fracture the femur. The 6-dimensional envelope generated in the current study provided a quantitative description of the strength of the femur-implant construct. All the femoral fractures were predicted in the trochanteric region, corresponding to where most in vivo fractures have been reported. The 6-dimensional envelopes developed in the current study may be useful in the design of fail-safe devices that could reduce femoral fractures in patients with bone-anchored percutaneous femoral implants. The framework presented may also be used for determining patient suitability for bone-anchored percutaneous implants, and for evaluating the functional performance of implant designs.

Scientific ReportsVol. 14(1)
The University of Melbourne (AU)
Australian Research Council
Openalex Percentile: Top 27%
Orthopaedic implants and arthroplasty
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A failure envelope approach to characterizing strength of an amputated femur with a bone-anchored percutaneous implant — Dale L. Robinson, Peter Vee Sin Lee, et al. · Scientific Reports (2024) | TGRS Research Map | TGRS