Phase Risk Analysis of Overhead Lines Under Complex Icing Conditions

Phase-to-ground discharge of transmission lines due to ice cover is a common issue. To assess the risk of phase-to-ground discharge of overhead lines under complex ice-covering conditions, this study used finite element analysis to model the interaction between ground wire, conductor, and insulator. The study examined how different factors affect the minimum safe distance between the conductor and ground wire, as well as the risk coefficient of phase-to-ground discharge and the risk zone. The finding reveals that as icing thickness increases, conductor bouncing intensifies, reducing the phase-to-ground distance, and placing one half of the line span within the risk zone for the given conditions. For the same length of de-icing, the closer the de-icing region is to the midpoint, the greater is the maximum jump height of the conductor. When the span is extended to 600 m, the risk range covers approximately 70% of the total line length. Under strong winds, conductor lateral displacement increases with wind speed, which leads to a higher risk of discharge.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-11-19
DOI
https://doi.org/10.3390/app142210701
Citations
3
Primary Topic
Icing and De-icing Technologies
Type
article
Field-Weighted Citation Impact
3.90
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase Risk Analysis of Overhead Lines Under Complex Icing Conditions

Yiran Zhang, Xinsheng Dong, Yongcan Zhu, Yuanhao Wan
3 citations
Applied Sciences
Icing and De-icing Technologies
3.90
article

Phase Risk Analysis of Overhead Lines Under Complex Icing Conditions

Yiran Zhang, Xinsheng Dong, Yongcan Zhu, Yuanhao Wan
article en
3 citations

Abstract

Phase-to-ground discharge of transmission lines due to ice cover is a common issue. To assess the risk of phase-to-ground discharge of overhead lines under complex ice-covering conditions, this study used finite element analysis to model the interaction between ground wire, conductor, and insulator. The study examined how different factors affect the minimum safe distance between the conductor and ground wire, as well as the risk coefficient of phase-to-ground discharge and the risk zone. The finding reveals that as icing thickness increases, conductor bouncing intensifies, reducing the phase-to-ground distance, and placing one half of the line span within the risk zone for the given conditions. For the same length of de-icing, the closer the de-icing region is to the midpoint, the greater is the maximum jump height of the conductor. When the span is extended to 600 m, the risk range covers approximately 70% of the total line length. Under strong winds, conductor lateral displacement increases with wind speed, which leads to a higher risk of discharge.

Applied SciencesVol. 14(22)
Xi'an Polytechnic University (CN), Inner Mongolia Electric Power (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 6%
Icing and De-icing Technologies
3.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.